DIEP皮瓣穿支特征对临床影响的ICG荧光成像前瞻性研究
该前瞻性研究纳入42例单侧DIEP皮瓣乳房再造,用吲哚菁绿荧光血管造影测量Zone 4灌注不足组织占比(Zone 4 %),评估穿支排、数量和直径对皮瓣微灌注的影响。结果显示内侧/外侧穿支排、穿支数量及直径在标准范围内均未显著影响Zone 4 %。
要点
- 内侧与外侧穿支排的Zone 4 %无显著差异(33.6±14.2% vs 29.9±7.5%,p=0.683)。
- 单穿支与双穿支的Zone 4 %无显著差异(31.5±14.4% vs 30.2±10.2%,p=0.727)。
- 穿支直径与Zone 4 %呈负相关趋势但无统计学意义(r=-0.096,p=0.588)。
核心结论
- 在标准范围内,穿支排选择、穿支数量及直径不影响ICG荧光造影所测的DIEP皮瓣Zone 4 %。
- Zone 4 %为DIEP皮瓣灌注的客观评估提供了新方法。
研究设计与样本
- 前瞻性临床研究,纳入42例单侧DIEP皮瓣乳房再造。
- 基于ICG荧光血管造影测量Zone 4灌注不足组织占全皮瓣重量的百分比(Zone 4 %)。
主要发现
- 内侧穿支排Zone 4 %为33.6±14.2%,外侧为29.9±7.5%,差异无统计学意义(p=0.683)。
- 单穿支Zone 4 %为31.5±14.4%,双穿支为30.2±10.2%,差异无统计学意义(p=0.727)。
- 穿支直径与Zone 4 %呈负相关趋势(r=-0.096,p=0.588)。
临床怎么用
- 在标准范围内,穿支排、数量和直径的选择可不作为DIEP皮瓣灌注优化的主要依据。
- ICG荧光造影测量的Zone 4 %可作为术中评估DIEP皮瓣灌注的客观指标。
局限性
- 样本量为42例单侧DIEP皮瓣乳房再造,结论外推需谨慎。
- 穿支直径与Zone 4 %仅呈负相关趋势,未达统计学意义。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The question to what extent perfusion in deep inferior epigastric perforator (DIEP) flaps depends on specific perforator characteristics has been raised. Anatomical studies and previous clinical trials focussing on DIEP flap perfusion resulted in discrepancies. This prospective study investigates how perforator row, number and diameter affect DIEP flap microperfusion via Indocyanine Green (ICG) fluorescence angiography. METHODS: The fractional weight of insufficiently perfused flap tissue in Zone 4 related to the total DIEP flap weight was measured based on ICG fluorescence angiography and defined as Zone 4 %. As a surrogate for overall DIEP flap perfusion, Zone 4 % was assessed according to the row, number and diameter of perforators included in the flap. RESULTS: In 42 unilateral DIEP flap breast reconstructions, neither medial (33.6 ± 14.2 %)/lateral perforator row (29.9 ± 7.5 %, p = 0.683) nor the parameter perforator number (single perforator 31.5 ± 14.4 %, two perforators 30.2 ± 10.2 %, p = 0.727) had a statistically significant effect on flap tissue availability as measured via Zone 4 %. A negative correlative trend between perforator diameter and Zone 4 % (r = -0.096, p = 0.588) was observed. CONCLUSION: Zone 4 % provides a novel method for an objective assessment of DIEP flap perfusion. Medial/lateral row selection and other perforator properties (number, diameter) within the standard ranges, did not affect Zone 4 % as indicated by ICG fluorescence angiography.
引用
- Anker AM, Prantl L, Strauss C, et al. Clinical Impact of DIEP Flap Perforator Characteristics - A Prospective Indocyanine Green Fluorescence Imaging Study. J Plast Reconstr Aesthet Surg. 2020. PMID: 32507580. doi:10.1016/j.bjps.2020.01.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。