文献速递瘢痕与激光烧伤

剪切波弹性成像定量评估烧伤瘢痕硬度的初步效度证据

Objective quantification of burn scar stiffness using shear-wave elastography: Initial evidence of validity.
PubMed 文献 · Burns · 2020-05-19

本研究为横断面研究,纳入32名参与者、48处烧伤瘢痕及48处配对侧对照,采用剪切波弹性成像(SWE)测量速度并与温哥华瘢痕量表(VSS)和患者与观察者瘢痕评估量表(POSAS)触觉子评分比较。结果显示瘢痕测量速度与两量表弹性子评分高度相关(r>0.7),速度差值与两量表中度相关(r>0.6);回归分析提示瘢痕速度增高与烧伤后时间及性别有关,身体部位和Fitzpatrick皮肤类型亦显著相关,年龄无显著关联。结论认为SWE有潜力作为量化烧伤瘢痕硬度的新工具,但解读时需考虑患者因素,建议扩大瘢痕多样性进一步研究。

要点

  • SWE测量的瘢痕速度与VSS和POSAS弹性子评分高度相关(r>0.7)。
  • 速度差值与VSS和POSAS弹性子评分中度相关(r>0.6)。
  • 瘢痕速度受烧伤后时间、性别、部位和皮肤类型影响,年龄无显著关联。

核心结论

  • 剪切波弹性成像(SWE)有潜力作为量化烧伤瘢痕硬度的新工具,但解读结果时需考虑患者因素。

研究设计与样本

  • 横断面研究,纳入32名参与者,评估48处烧伤瘢痕和48处配对对侧对照部位,使用SWE、温哥华瘢痕量表(VSS)和患者与观察者瘢痕评估量表(POSAS)触觉子评分。

主要发现

  • Spearman's rho显示瘢痕测量速度与POSAS和VSS弹性子评分高度相关(r>0.7),计算的速度差值与两量表中度相关(r>0.6)。
  • 回归分析表明瘢痕速度增高与烧伤后时间长短和性别有关,身体部位和Fitzpatrick皮肤类型也与速度显著相关,而年龄无显著关联。

临床怎么用

  • SWE可用于定量评估烧伤瘢痕硬度,但临床解读时应考虑烧伤后时间、性别、身体部位和Fitzpatrick皮肤类型等患者因素。

局限性

  • 结论基于32名参与者和48处瘢痕的横断面数据,作者建议在更大且更多样的瘢痕样本中进一步研究以支持现有发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: Shear-wave elastography (SWE) is an ultrasound based technology that can provide reliable measurements (velocity) of scar stiffness. The aim of this research was to evaluate the concurrent validity of using both the measured velocity and the calculated difference in velocity between scars and matched controls, in addition to evaluating potential patient factors that may influence the interpretation of the measurements. METHODS: A cross-sectional study of 32 participants, with 48 burn scars and 48 matched contralateral control sites were evaluated with SWE, the Vancouver Scar Scale (VSS) and the Patient and Observer Scar Assessment Scale (POSAS) tactile sub-scores. RESULTS: Spearman's rho demonstrated high correlations (r > 0.7) between the measured scar velocity and both the POSAS and VSS pliability sub-scores, whereas moderate correlations (r > 0.6) were found with the calculated difference in velocity. Regression analysis indicated that the association of increased velocity in scars, varied by length of time after burn injury and gender. Body location and Fitzpatrick skin type also demonstrated significant associations with velocity, whereas age did not. CONCLUSION: SWE shows potential as a novel tool to quantify burn scar stiffness, however patient factors need to be considered when interpreting results. Further research is recommended on a larger variety of scars to support the findings.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. DeJong H, Abbott S, Zelesco M, et al. Objective quantification of burn scar stiffness using shear-wave elastography: Initial evidence of validity. Burns. 2020. PMID: 32534890. doi:10.1016/j.burns.2020.05.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。