基于美国全国住院患者样本2002至2014年数据,急性烧伤患者中526例接受皮瓣手术(0.17%),皮瓣并发症发生率为6.4%。皮瓣覆盖时机与并发症无关,电击伤是皮瓣并发症的唯一独立预测因素(OR 40.49)。

要点

  • 急性烧伤皮瓣手术时机不影响并发症发生。
  • 电击伤是皮瓣并发症的独立预测因素。
  • 皮瓣手术在急性烧伤创面闭合中是安全的。

核心结论

  • 皮瓣手术时机与因并发症返回手术室无关。
  • 电击伤是皮瓣并发症的独立预测因素。

研究设计与样本

  • 利用美国全国住院患者样本2002至2014年数据,基于ICD-9编码提取急性烧伤患者,加权样本306,924例次,其中526例接受皮瓣手术(0.17%)。

主要发现

  • 皮瓣并发症发生于6.4%的病例。
  • 电击伤在皮瓣病例中占7.8%,非皮瓣病例中占2.7%(OR 3.76,95%CI 1.95-7.24,P < .001)。
  • 皮瓣手术的平均住院日为10.1天(SD 10.7)。
  • 电击伤是皮瓣并发症的唯一独立预测因素(OR 40.49,95%CI 2.98-550.64,P = .005)。

关键数值与推荐

  • 皮瓣并发症定义为ICD-9手术编码86.75,即返回手术室进行皮瓣修整。

临床怎么用

  • 急性烧伤创面闭合中使用皮瓣是安全的,但电击伤需特别考虑以避免失败。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Pedicled and free flaps are occasionally necessary to reconstruct complex wounds in acute burn patients. Flap coverage has classically been delayed for concern of progressive tissue necrosis and flap failure. We aim to investigate flap complications in primary burn care leveraging national U.S. data. Acute burn patients with known % total body surface area(TBSA) were extracted from the Nationwide/National Inpatient Sample from 2002 to 2014 based on the International Classification of Disease (ICD) codes, ninth edition. Variables included age, sex, race, Elixhauser index, %TBSA, mechanism, inhalation injury, and location of burn. Flap complication was defined by ICD-9 procedure code 86.75, return to the operating room for flap revision. Multivariable analysis evaluated predictors of flap compromise using stepwise logistic regression with backward elimination. The weighted sample included 306,924 encounters of which 526 received a flap (0.17%). About 7.8% of flap encounters sustained electric injury compared to 2.7% of non-flap encounters (odds ratio [OR] 3.76, 95% confidence interval [CI] 1.95-7.24, P < .001). The mean hospital day of the flap procedure was 10.1 (SD 10.7) days. Flap complications occurred in 6.4% of cases. The timing of flap coverage was not associated with complications. The only independent predictor of flap complication was electrical injury (OR 40.49, 95% CI 2.98-550.64, P = .005). Electrical injury was an independent predictor of flap complications compared to other mechanisms. Flap timing was not associated with return to surgery for complications. This suggests that the use of flaps is safe in acute burn care to achieve burn wound closure with an understanding that electrical injuries may warrant particular consideration to avoid failure.

来源:J Burn Care Res,查看原文。版权归原作者所有。

引用

  1. Perrault D, Rochlin D, Pham C, et al. Timing of Flap Surgery in Acute Burn Patients Does Not Affect Complications. J Burn Care Res. 2020. PMID: 32582915. doi:10.1093/jbcr/iraa096

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。