文献速递烧伤创面修复

利用血流搏动性提高激光散斑对比成像评估烧伤深度的准确性

Using blood flow pulsatility to improve the accuracy of laser speckle contrast imaging in the assessment of burns.
PubMed 文献 · Burns · 2020-04-13

该研究在32例患者187个感兴趣区于伤后0-5天用激光散斑对比成像测量灌注与搏动性,发现8秒记录时长搏动性重复性良好(%CV: 15.9%),伤后0-2天搏动性<1.45 (Perfusion Units)²预测手术需求敏感度和特异度均为100%。结论认为测量搏动性可提高LSCI评估烧伤的准确性,并能在伤后0-2天高精度预测手术需求。

要点

  • 伤后0-2天搏动性<1.45 (Perfusion Units)²可高精度预测手术需求。
  • 搏动性测量推荐记录时长8秒,重复性良好(%CV: 15.9%)。
  • 伤后0-2天与3-5天搏动性无显著差异,但灌注在3-5天显著更高。

核心结论

  • 测量血流搏动性可提高LSCI评估烧伤的准确性,并能在伤后0-2天高精度预测手术需求。

研究设计与样本

  • 前瞻性研究,纳入32例患者共187个感兴趣区,伤后0-5天用LSCI测量灌注与搏动性,并测试1-12秒记录时长的搏动性重复性。

主要发现

  • 8秒记录时长搏动性重复性良好(%CV: 15.9%),更长时长仅小幅提高评估准确性。
  • 伤后0-2天搏动性<1.45 (Perfusion Units)²预测手术需求的敏感度100%(95% CI: 83.2-100%)、特异度100%(95% CI: 95.2-100%)、阳性预测值100%、阴性预测值100%。
  • 伤后0-2天与3-5天搏动性无显著差异;对于3周内愈合的创面,伤后3-5天灌注显著高于0-2天。

关键数值与推荐

  • 搏动性cut-off值<1.45 (Perfusion Units)²用于伤后0-2天预测手术需求。
  • 搏动性测量推荐记录时长8秒。

临床怎么用

  • 可在伤后0-2天采用LSCI测量搏动性(8秒记录),以搏动性<1.45 (Perfusion Units)²辅助判断手术需求。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Measurement of perfusion is an established method to evaluate the depth of burns. However, high accuracy is only achievable >48 h after injury. The aim of the study was to investigate if measurement of blood flow pulsatility, combined with perfusion measurement, can improve early assessment of burn depth using laser speckle contrast imaging (LSCI). METHODS: Perfusion and pulsatility were measured with LSCI in 187 regions of interest in 32 patients, between 0 and 5 days after injury. The reproducibility of pulsatility was tested for recording durations between 1 and 12 s. The most reproducible duration was chosen, and receiver operator characteristics were created to find suitable pulsatility cut-offs to predict surgical need. RESULTS: A measurement duration of 8 s resulted in a good reproducibility of the pulsatility (%CV: 15.9%). Longer measurement durations resulted in a small improvement of the accuracy of the assessment. A pulsatility of <1.45 (Perfusion Units)2 on day 0-2 after injury predicted surgical need with a sensitivity of 100% (95% CI: 83.2-100%), specificity of 100% (95% CI: 95.2-100%), a positive predictive value of 100%, and a negative predictive value of 100%. Pulsatility was not significantly different when comparing measurements done day 0-2 to day 3-5. Perfusion was however significantly higher day 3-5 compared to day 0-2 for wounds healing within 3 weeks. CONCLUSION: Measurement of pulsatility improves the accuracy of the assessment of burns with LSCI and makes it possible to predict the need for surgery during day 0-2 after injury with a high accuracy.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Mirdell R, Farnebo S, Sjöberg F, et al. Using blood flow pulsatility to improve the accuracy of laser speckle contrast imaging in the assessment of burns. Burns. 2020. PMID: 32299641. doi:10.1016/j.burns.2020.03.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。