简化血糖反应整合的持续胰岛素输注算法降低烧伤中心低血糖发生率
该回顾性研究评估了一种基于血糖反应调整剂量的持续胰岛素输注新算法在烧伤患者中的实施后表现。新算法经过两年六次迭代后实施,结果显示低血糖发生率显著降低(0.6% vs 0.2%,P < .001),而中位血糖水平和目标血糖范围内时间无显著差异。感染、住院时长和生存率亦无差异。
要点
- 新持续胰岛素输注算法实施后低血糖发生率显著降低(0.6% vs 0.2%,P < .001)。
- 中位血糖水平和目标血糖范围内时间两组间无显著差异。
- 感染、住院时长和生存率未见差异。
核心结论
- 整合血糖反应的单一动态持续胰岛素输注算法可降低烧伤患者低血糖发生率。
主要发现
- 低血糖发生率实施后显著低于实施前(0.6% vs 0.2%,P < .001)。
- 中位血糖水平两组无差异(149.9 vs 146.5 mg/dl,P = .56)。
- 目标血糖范围内时间无显著差异(13.8 vs 14.7 h/day,P = 0.23)。
- 感染、住院时长和生存率无差异。
关键数值与推荐
- 目标血糖范围定义为70-149 mg/dl。
- 共评估5239个床旁血糖值。
临床怎么用
- 可采用基于血糖反应调整剂量的持续胰岛素输注算法以降低低血糖风险。
- 加强教育和随访血糖监测可能进一步改善目标血糖范围内时间。
局限性
- 回顾性研究设计,样本量较小(20份记录),可能存在未测量的混杂因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Attaining adequate glycemic control in burn patients has been shown to reduce infection-related mortality. Previous internal evaluation of continuous insulin infusion (CII) use revealed a hypoglycemia rate of 0.6% and an average time within goal glycemic range (70-149 mg/dl) of 13.8 h/day. A new algorithm, designed to adjust dosage based on glycemic response, underwent six iterations over 2 years before the final version was implemented. The purpose of this retrospective study was to assess the post-implementation performance of the newly developed CII algorithm. The current study was powered to detect a 50% reduction in hypoglycemic events, as compared to a pre-implementation historical control. The cohort was 62% male with a mean age of 54.5 ± 17.4. Sixty-five percent had thermal injuries with a median 23.5 (11-45) %TBSA. There were no differences in demographics between groups. Among the 20 records reviewed, 5239 point-of-care glucose values were assessed. Post-implementation, hypoglycemia rates were significantly lower (0.6% vs 0.2%; P < .001). There was no difference in median blood glucose between groups (149.9 vs 146.5 mg/dl; P = .56). Time spent within goal glycemic range was not significantly different (13.8 vs 14.7 h/day; P = 0.23). There were no differences in infection, length of stay, or survival. The consolidation, education, and implementation of a single, dynamic CII algorithm reduced the incidence of hypoglycemia. The authors expect that education and diligence with follow-up glucose monitoring will further improve time within goal glycemic range by preventing rebound hyperglycemia.
引用
- Hendrix HA, Velamuri SR, Sultan-Ali I, et al. Simplified Approach to Incorporating Glycemic Response Within a Continuous Insulin Infusion Algorithm to Improve the Incidence of Hypoglycemia in a Single Burn Center. J Burn Care Res. 2020. PMID: 32249298. doi:10.1093/jbcr/iraa058
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。