堆叠皮瓣乳房再造中逆行胸廓内血管吻合的重新审视:受区选择算法
该回顾性研究分析了2011至2018年153例患者共400个堆叠皮瓣乳房再造,比较颅侧、尾侧胸廓内血管及瓣内血管吻合的并发症。术后吻合口并发症仅由静脉问题引起,占3%,其中尾侧吻合血栓导致皮瓣丢失比例显著高于颅侧或瓣内吻合(P=0.020)。作者建议若血管条件相当,第二受区应优先选择瓣内血管。
要点
- 堆叠皮瓣第二吻合可选颅侧、尾侧胸廓内血管或瓣内血管。
- 术后吻合口并发症仅由静脉问题引起,发生率为3%。
- 尾侧吻合血栓致皮瓣丢失比例显著高于其他部位。
核心结论
- 若尾侧胸廓内血管与瓣内血管条件相当,堆叠皮瓣再造的第二受区吻合应选择瓣内血管。
研究设计与样本
- 回顾性综述了2011至2018年在本机构进行的多皮瓣乳房再造,包括双蒂DIEP、堆叠PAP及堆叠PAP/DIEP。
- 共纳入153例患者,完成400个堆叠皮瓣。
主要发现
- 400个动脉吻合中,200个(50%)吻合至颅侧胸廓内血管,141个(35.3%)至尾侧胸廓内血管,59个(14.8%)至瓣内血管。
- 435个静脉吻合中,145个(33.3%)吻合至尾侧胸廓内血管,201个(46.2%)至颅侧胸廓内血管,89个(20.5%)至瓣内血管。
- 术中因血栓修正:尾侧动脉8.5%(12/141),颅侧动脉7%(14/20),瓣内动脉11.9%(7/59),P=0.373;静脉吻合中尾侧无,颅侧1.5%(3/201),瓣内2.2%(2/89),P=0.559。
- 术后吻合口并发症发生于12/400个皮瓣(3%),均归因于静脉问题;其中7/12(58.3%)挽救成功,5/12(41.7%)失败。
- 因血栓导致皮瓣丢失:尾侧4/5(80%),颅侧1/5(20%),瓣内0/5,P=0.020。
临床怎么用
- 在堆叠皮瓣乳房再造中,选择第二受区吻合血管时,若尾侧胸廓内血管与瓣内血管条件相当,应优先使用瓣内血管以降低皮瓣丢失风险。
局限性
- 本研究为回顾性设计,证据等级为治疗性III级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The authors present their stacked flap breast reconstruction experience to facilitate selection of either caudal internal mammary vessels or intraflap vessels for the second recipient anastomosis. METHODS: A retrospective review was conducted of multiflap breast reconstructions (double-pedicled deep inferior epigastric perforator, stacked profunda artery perforator, and stacked profunda artery perforator/deep inferior epigastric perforator) performed at the authors' institution from 2011 to 2018. Data collected included demographics, recipient vessels used, and intraoperative/postoperative flap complications. Complications were compared between cranial, caudal, and intraflap anastomoses. RESULTS: Four hundred stacked flaps were performed in 153 patients. Of 400 arterial anastomoses, 200 (50 percent) were to cranial internal mammary vessels, 141 (35.3 percent) were to caudal internal mammary vessels, and 59 (14.8 percent) were to intraflap vessels. Of 435 venous anastomoses, 145 (33.3 percent) were to caudal internal mammary vessels, 201 (46.2 percent) were to cranial internal mammary vessels, and 89 (20.5 percent) were to intraflap vessels. Intraoperative revision for thrombosis occurred in 12 of 141 caudal (8.5 percent), 14 of 20 cranial (7 percent), and seven of 59 intraflap (11.9 percent) arterial anastomoses (p = 0.373), and in none of caudal, three of 201 cranial (1.5 percent), and two of 89 intraflap (2.2 percent) venous anastomoses (p = 0.559). Postoperative anastomotic complications occurred in 12 of 400 flaps (3 percent) and were exclusively attributable to venous compromise; seven of 12 (58.3 percent) were salvaged, and five of 12 (41.7 percent) were lost. More lost flaps were caused by caudal [four of five (80 percent)] versus cranial [one of five (20 percent)] or intraflap (zero of five) thrombosis (p = 0.020). CONCLUSION: If vessel features are equivalent between the caudal internal mammary vessels and intraflap vessels, intraflap vessels should be used for second site anastomosis in stacked flap reconstructions. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.