机械通气作为严重烧伤患者腹腔间隙综合征(ACS)发病诊断替代指标
结果显示ACS组所有通气压力均显著升高,早期与晚期ACS亚组最大PEEP和峰值压力均显著升高,平均通气压力仅在早期ACS组升高。建议机械通气烧伤患者通气压力持续升高且无明确原因时测量腹腔内压。
要点
- ACS组最大及平均PEEP、峰值压力均显著高于对照组。
- 早期和晚期ACS亚组最大PEEP及峰值压力均显著升高。
- 平均PEEP(p=0.0069)和平均峰值压力(p=0.05)仅在早期ACS组升高。
核心结论
- ACS组通气压力显著升高,可作为支持早期诊断的替代指标。
- 早期和晚期ACS患者最大PEEP和峰值压力均显著升高。
研究设计与样本
- ACS组按烧伤至ACS中位时间分为早期和晚期ACS亚组。
- 采用双侧Mann-Whitney U检验,显著性设定为p<0.05。
主要发现
- ACS组所有通气压力(最大及平均PEEP、峰值压力)较对照组显著升高。
- 早期和晚期ACS亚组最大PEEP和峰值压力较对照组显著升高。
- 平均PEEP(p=0.0069)和平均峰值压力(p=0.05)仅在早期ACS组显著升高。
关键数值与推荐
- 建议在机械通气烧伤患者通气压力持续升高且无明确肺部或其他原因时测量腹腔内压,作为对现行WSACS指南的补充。
临床怎么用
- 对机械通气烧伤患者,若通气压力持续升高且无明确原因,应测量腹腔内压以早期识别ACS。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Intra-abdominal compartment syndrome (ACS) is a devastating complication in burn patients with a high mortality. Apart from high-volume resuscitation as known risk factor, also mechanical ventilation seems to influence the development of ACS. The TIRIFIC trial is a retrospective, matched-pair analysis. Thirty-eight burn patients with ACS were matched for burned total body surface area (TBSA), age and mechanical ventilation (MV). In contrast to the already published part I addressing fluid resuscitation as a risk factor, the parameters analyzed in part II were maximum and average PEEP and peak pressure levels as well as serum lactate levels and prokinetic therapy. For subgroup-analysis the ACS-group was split up into an early-onset and late-onset ACS-group according to the median time between burn trauma and ACS. The groups were analyzed with a two-sided Mann-Whitney-U-test with significance set at p < 0.05. In the ACS-group all ventilation pressures (maximum and average PEEP and peak pressure levels) were significantly increased compared to control. The subgroup-analysis showed significantly increased maximum PEEP and peak pressure levels in early- and late-onset ACS-groups versus control. However, the average ventilation pressure levels were only increased in the early-onset ACS-group (average PEEP p = 0.0069; average peak pressure p = 0.05). The TIRIFIC trial showed significantly increased ventilation pressures in the ACS group in general as a surrogate parameter to support early diagnostics. Especially, maximum PEEP levels and peak pressures are significantly increased in both, early- and late-onset ACS. As an addition to the actual WSACS guidelines we suggest IAP measurement in mechanically ventilated burn patients if ventilating pressures are rising continuously without a clear pulmonary or otherwise identifiable reason.
引用
- Boehm D, Arras D, Schroeder C, et al. Mechanical ventilation as a surrogate for diagnosing the onset of abdominal compartment syndrome (ACS) in severely burned patients (TIRIFIC-study Part II). Burns. 2020. PMID: 32122710. doi:10.1016/j.burns.2020.02.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。