新型烧伤装置在小鼠模型中快速可重复制作烧伤
研究开发了一种含加热金属探针和温度传感器的烧伤装置,在小鼠背部以60°C、80°C、100°C接触40秒制作烧伤,24小时后活检。结果显示装置可精确均匀致伤,烧伤形态呈温度依赖差异,仅100°C可见凝固、淤滞和充血三带及严重血管损伤。
要点
- 新型装置可精确控制温度与时间,在小鼠中均匀制作烧伤。
- 100°C接触40秒可见凝固、淤滞、充血三带及严重血管损伤。
- 60°C和80°C组血管灌注较对照分别高14%和57%,100°C组低53%。
核心结论
- 该装置能在小鼠模型中产生精确且均匀的烧伤创面,可能用于烧伤研究和创面护理产品验证。
研究设计与样本
- 动物实验研究,使用新开发的烧伤装置(加热金属探针与热传感器)在小鼠背部制作烧伤。
- 动物分为不同组,分别以60°C、80°C和100°C接触40秒致伤。
- 伤后24小时采集皮肤活检进行组织病理学分析,并用VesSeg工具检测血管损伤。
主要发现
- 不同温度组烧伤形态呈温度依赖的显著差异,但各组烧伤面积无显著差异。
- 100°C组可见凝固、淤滞和充血三带,80°C和60°C组三带不明显。
- 组织病理学显示角质层、表皮、真皮、胶原和毛囊损伤程度随温度不同而异。
- 严重血管损伤仅见于100°C组。
- 与对照相比,60°C和80°C组血管灌注分别高14%和57%,100°C组因血管损伤最重而降低53%。
临床怎么用
- 该装置可为烧伤相关研究提供可重复的动物模型,减少人工操作变异。
- 选择60°C、80°C或100°C接触40秒可复制不同深度和血管损伤程度的烧伤。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The currently available practices for creation of burns in the animals are mostly manual which may lead to lack of uniform wound. There is a need to develop a suitable device that could reproduce and uniformly create burn wound in animal models without the procedural variations and human variability. Present study deals with development of a burn device which has been designed for creation of animal models for burn injury. METHODS: The designed burn device comprises of two main components a heating metal stylus and the thermal sensor. Metal stylus consists of two parts with top part acts as handle and bottom part contains the aluminum probe which quickly heats and cool. The temperature monitoring sensor is attached adjacent to the tip of the probe. The temperature and timer are digitally displayed and can be adjusted as per the requirement. This device is tested for creation of uniform burn in the mice model. Animals were divided into different groups and thermal burn was generated for 60 °C, 80 °C & 100 °C respectively. Burn wound was generated dorsally on shaved skin with contact time of 40 s. Skin biopsies of burn wound were collected after 24 h for histopathology analysis to determine the burn characteristics. Blood vessels damage in the skin was detected by transillumination and digital segmentation using VesSeg tool. RESULTS: The device is able to deliver the different temperature to the animal skin. After reaching the 60 °C, 80 °C & 100 °C for 40 s respectively electronic relays shut down the device. The different groups of the animals showed significant difference in burn morphology in temperature dependent manner. Non significant variation in the burn area of different experimental groups animals was observed. All three zones vis-a-vis coagulation, stasis and hyperaemia were observed at 100 °C whereas found indistinct in 80 °C and 60 °C treated groups. Histopathological studies clearly demonstrated the differences in damage induction in stratum corneum, epidermis, dermis, collagen and hair follicle at selected thermal points. Severe blood vessels damage was observed only at 100 °C. The vascular perfusion was recorded 14% and 57% higher in 60 °C and 80 °C treated animals respectively when compared to control animals. However, at 100 °C due to highest vessel damage the perfusion was reduced to 53% compared to control. CONCLUSION: Present study demonstrates that the device is able to generate precise and uniform burn wound in mice model. The device may be useful for burn related studies and validation of burn wound care products.
引用
- Shukla SK, Sharma AK, Shaw P, et al. Creation of rapid and reproducible burn in animal model with a newly developed burn device. Burns. 2020. PMID: 32169381. doi:10.1016/j.burns.2019.12.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。