文献速递乳房整形与再造显微修复重建

腹壁下浅动脉皮瓣动静脉解剖的CT血管造影回顾性研究

Anatomy of the arterial and venous systems of the superficial inferior epigastric artery flap: A retrospective study based on computed tomographic angiography.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2019-11-28

该研究回顾性分析72例患者双侧下腹壁MDCTA,评估SIEA及其伴行静脉的解剖。SIEA存在率92.4%,平均内径2.0mm,70.8%侧别内径≥2.0mm。结论认为SIEA起始内径≥2.0mm可作为术中探查动脉的筛选标准。

要点

  • SIEA存在率92.4%,平均内径2.0mm,70.8%侧别≥2.0mm
  • VC在47.2%侧别汇入旋髂浅静脉,20.8%汇入SIEV
  • 术前MDCTA评估SIEA内径≥2.0mm可指导皮瓣动脉探查

核心结论

  • SIEA起始内径≥2.0mm可作为下腹壁皮瓣切取时探查动脉的良好标准。
  • VC在某些患者中是优于SIEV的主要引流静脉,且近半数患者VC与旋髂浅静脉交通。

研究设计与样本

  • 回顾性分析72例连续患者双侧下腹壁术前MDCTA结果。

主要发现

  • SIEA存在于133侧(92.4%),平均内径2.0mm。
  • SIEA内径≥2.0mm见于102侧(70.8%)。
  • VC汇入旋髂浅静脉68侧(47.2%),汇入SIEV 30侧(20.8%)。

关键数值与推荐

  • SIEA起始内径≥2.0mm(术前影像)作为动脉探查标准。
  • VC为优势引流静脉,近半数与旋髂浅静脉交通。

临床怎么用

  • 术前MDCTA测量SIEA内径≥2.0mm可提高皮瓣动脉探查成功率。
  • 关注VC作为优势引流静脉及与旋髂浅静脉的交通,可提高SIEA皮瓣乳房再造安全性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study was performed to investigate the arterial and venous anatomy of superficial inferior epigastric artery (SIEA) flaps using multidetector-row computed tomography angiography (MDCTA). We hypothesized that applicability of the SIEA flap has been underestimated in previous studies. METHODS: We retrospectively analyzed the results of preoperative MDCTA of the bilateral lower abdominal walls in 72 consecutive patients. We assessed the presence and branching pattern of the superficial inferior epigastric artery, superficial inferior epigastric vein (SIEV), superficial circumflex iliac vein, and venae comitantes (VC) of the superficial inferior epigastric artery. We also assessed the internal diameter of the SIEA at its origin. RESULTS: The SIEA was present on 133 sides (92.4%), and the mean internal diameter was 2.0 mm. The internal diameter of the SIEA was ≥2.0 mm on 102 sides (70.8%). The VC drained into the superficial circumflex iliac vein on 68 sides (47.2%) and to the SIEV on 30 sides (20.8%). CONCLUSIONS: An internal diameter of the SIEA of ≥2.0 mm at its origin on preoperative imaging can be a good criterion for exploring the artery during lower abdominal flap harvest. The VC is the dominant drainage vein over the SIEV in some patients, and it communicates with the superficial circumflex iliac vein in almost half of patients. These findings can increase the safety of breast reconstruction with an SIEA flap.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Kita Y, Fukunaga Y, Arikawa M, et al. Anatomy of the arterial and venous systems of the superficial inferior epigastric artery flap: A retrospective study based on computed tomographic angiography. J Plast Reconstr Aesthet Surg. 2019. PMID: 32085972. doi:10.1016/j.bjps.2019.11.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。