文献速递乳房整形与再造显微修复重建

扩大背阔肌肌皮瓣联合即刻脂肪移植在即刻乳房重建中塑造解剖型乳房

Shaping an Anatomical Breast Using Extended Latissimus Dorsi Flap and Lipofilling in Immediate Breast Reconstruction.
PubMed 文献 · Ann Plast Surg · 2020-01-01

该研究回顾性分析了45例接受单侧即刻乳房重建的患者,采用扩大背阔肌肌皮瓣180度旋转联合即刻脂肪移植的技术。结果显示该技术可重塑具有恒定尺寸、合适宽度、高度和凸度的乳房,无皮瓣或脂肪坏死,供区血清肿9例。作者认为该技术简单易行,为乳房重建提供了额外的自体组织选择。

要点

  • 扩大背阔肌肌皮瓣180度旋转联合即刻脂肪移植可塑造恒定尺寸的乳房。
  • 45例患者平均年龄46岁,平均BMI 23.1 kg/m²,平均乳房切除标本重量299.0 g。
  • 平均皮岛18.8×8.7 cm,皮瓣内注射脂肪71.0 mL,无皮瓣或脂肪坏死。

核心结论

  • 扩大背阔肌肌皮瓣联合脂肪移植可重建具有恒定尺寸、合适宽度、高度和凸度的乳房。
  • 塑造背阔肌肌皮瓣并不困难或不可预测,该技术简单易行。
  • 该技术为乳房重建提供了额外的自体组织选择。

研究设计与样本

  • 回顾性综述接受单侧即刻乳房重建的患者的资料。
  • 患者接受扩大背阔肌肌皮瓣联合即刻脂肪移植。
  • 共纳入45例患者,平均年龄46岁,平均BMI 23.1 kg/m²。

主要发现

  • 平均乳房切除标本重量为299.0 g。
  • 平均获取皮岛大小为18.8×8.7 cm,皮瓣内注射脂肪71.0 mL。
  • 供区血清肿发生于9例患者,未发现皮瓣或脂肪坏死。

临床怎么用

  • 对于需要自体组织乳房重建的患者,可考虑采用扩大背阔肌肌皮瓣联合即刻脂肪移植的技术。
  • 术中可将背阔肌肌皮瓣180度旋转并结合即刻脂肪移植以塑造自然乳房形态。
  • 需注意供区血清肿的发生,本研究中9例患者出现该并发症。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although many attempts have been made to augment the volume of the latissimus dorsi (LD) myocutaneous flap in breast reconstruction, only a few studies on the shaping of the LD flap to achieve a natural native breast have been conducted. We introduce our novel method to reconstruct a naturally shaped breast by combining an extended LD myocutaneous flap with immediate lipofilling. METHODS: The patients who underwent an immediate unilateral breast reconstruction with an extended LD myocutaneous flap and lipofilling were retrospectively reviewed. The extended LD myocutaneous flap in 180-degree rotation was combined with an immediate lipofilling procedure followed by suturing to reproduce the constant dimensions of a neobreast. RESULTS: A total of 45 patients with a mean age of 46 years and an average body mass index of 23.1 kg/m were enrolled. The average weight of the mastectomy specimens was 299.0 g. An average 18.8 × 8.7-cm skin paddle within the flap was harvested, and 71.0 mL of fat was injected into the flap. Donor site seroma was found in 9 patients, and no flap or fat necrosis was found. CONCLUSIONS: Our technique of extended LD muscle flap with lipofilling reproduced breasts with constant dimensions and appropriate width, height, and projection. Shaping the LD muscle flap is not difficult or unpredictable. This is a simple and easy technique to shape the LD flap and will provide surgeons with an additional autologous option for breast reconstruction.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Cha HG, Kwon JG, Kim EK, et al. Shaping an Anatomical Breast Using Extended Latissimus Dorsi Flap and Lipofilling in Immediate Breast Reconstruction. Ann Plast Surg. 2020. PMID: 32040003. doi:10.1097/SAP.0000000000002295

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。