感觉性股深动脉穿支皮瓣用于自体乳房再造的解剖学研究
本研究通过显微解剖10具尸体下肢,探讨股后皮神经(PFCN)分支在股深动脉穿支(PAP)皮瓣分布区内的走行及与表面标志的关系。结果显示PAP皮瓣区内平均有3条PFCN分支,并测得分支至臀沟及后正中线的距离、直径和长度,为感觉性PAP皮瓣的临床应用提供解剖学依据。
要点
- PAP皮瓣区内平均有3条PFCN分支供应感觉。
- 神经分支位于臀沟尾侧平均2.4 cm、后正中线内侧平均4.3 cm。
- 神经分支平均直径1.8 mm,从皮瓣至筋膜平均长2.0 cm。
核心结论
- 本研究为感觉性PAP皮瓣提供了解剖学基础,可能为自体乳房再造增加感觉功能维度。
- 初步结果有前景,但需进一步生理学研究验证感觉性PAP皮瓣的应用。
研究设计与样本
- 解剖学研究,显微外科解剖10具尸体下肢。
- 研究股后皮神经(PFCN)在PAP皮瓣分布区的分支,以大腿后侧正中线和臀沟为表面标志。
主要发现
- PAP皮瓣分布区内发现2至5条PFCN分支,平均3条。
- 神经分支至臀沟尾侧平均距离2.4 cm(范围0至7 cm)。
- 神经分支至后正中线内侧平均距离4.3 cm(范围0.2至8.1 cm)。
- 神经分支平均直径1.8 mm(范围1至2.5 mm)。
- 神经分支从皮瓣至筋膜平均长度2.0 cm(范围1.5至2.4 cm),肌内追踪至PFCN主干最大长度7.8 cm。
临床怎么用
- 在PAP皮瓣乳房再造中,可参考臀沟尾侧约2.4 cm、后正中线内侧约4.3 cm的区域寻找PFCN分支。
- 神经分支直径约1.8 mm、至筋膜长度约2.0 cm,可作为术中神经分离的解剖参考。
局限性
- 本研究为尸体解剖研究,样本量为10具下肢。
- 感觉性PAP皮瓣的生理学功能尚未验证,需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The profunda artery perforator (PAP) flap has been demonstrated to be an effective method of autologous breast reconstruction, particularly when the abdominal donor site is contraindicated. However, there are no current reports regarding the use of a sensate PAP flap in this type of reconstruction. The objective of this study is to describe the feasibility and anatomic location of the sensory nerves supplying the PAP flap in relation to surface landmarks for use in autologous breast reconstruction. METHODS: In this anatomic study, 10 cadaver lower limbs were microsurgically dissected. We investigated the posterior femoral cutaneous nerve (PFCN), which supplies sensation to the skin of the posterior thigh and distribution of the PAP flap. The midline of the posterior thigh and gluteal crease were used for surface landmarks. The diameter and length of the nerve branches were documented. RESULTS: There were between 2 and 5 PFCN branches, with an average of 3 branches, that were found within the distribution of the PAP flap. Measurements were taken from the gluteal crease and midline to the nerve branches. The average distance caudal to the gluteal crease was 2.4 cm (0 to 7 cm). The average distance medial to the midline was 4.3 cm (0.2 to 8.1 cm). The average diameter of the nerve branches was 1.8 mm (1 to 2.5 mm). The average length of nerve branches from the flap to the fascia was 2.0 cm (1.5 to 2.4 cm). The maximum length of the nerve branches from the flap to the main trunk of the PFCN was 7.8 cm when tracing the nerve branches intramuscularly. CONCLUSIONS: The findings from this study provide an anatomic basis for the sensate PAP flap that would potentially provide an additional dimension to the use of this perforator flap in autologous breast reconstruction. These preliminary results are promising, and further physiological studies are warranted to validate the use of this sensate flap.
引用
- Song B, Kumbla PA, Boyd C, et al. The Feasibility of a Sensate Profunda Artery Perforator Flap in Autologous Breast Reconstruction: An Anatomic Study for Clinical Application. Ann Plast Surg. 2020. PMID: 32028466. doi:10.1097/SAP.0000000000002275
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。