文献速递显微修复重建创面修复

游离腓骨瓣联合外固定架重建胫骨创伤性缺损

Reconstruction of Traumatic Defects of the Tibia With Free Fibula Flap and External Fixation.
PubMed 文献 · Ann Plast Surg · 2020-01-01

回顾性分析8例胫骨节段性缺损(平均10.2 cm)患者,采用游离腓骨瓣联合简单外固定架,再转换为六轴计算机辅助环形外固定架矫正残余畸形。所有患者均实现骨愈合和肢体挽救,但37.5%患者因移植骨骨折再入院。

要点

  • 游离腓骨瓣联合外固定架可有效重建胫骨节段性缺损并矫正残余畸形
  • 术后需关注移植骨骨折风险,本组37.5%患者因骨骨折再入院
  • 最终骨愈合率和肢体挽救率均达100%

核心结论

  • 游离腓骨瓣联合外固定架是治疗后创伤性胫骨缺损伴残余力线不良的可靠重建方案。

研究设计与样本

  • 回顾性病历回顾,纳入8例(8根胫骨)节段性缺损大于7 cm的患者,均行游离腓骨瓣联合简单钉杆外固定架,后转换为六轴计算机辅助多平面环形外固定架矫正残余骨畸形。

主要发现

  • 平均胫骨骨缺损为10.2 cm;所有肢体均有软组织缺损(平均面积138 cm)。
  • 游离腓骨移植物为骨皮瓣或骨肌皮瓣(平均长度12 cm)。
  • 并发症包括1例延迟愈合和3例(37.5%)患者因移植骨骨折再入院。
  • 最终100%患者实现移植骨愈合和残余肢体畸形满意矫正,肢体挽救率为100%。

临床怎么用

  • 对于胫骨节段性缺损伴残余成角畸形,可考虑游离腓骨瓣联合简单外固定架,再转换为计算机辅助环形外固定架矫正畸形并允许患者愈合期间活动。

局限性

  • 回顾性研究,样本量小(8例),无对照组,结果需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Traumatic intercalary defects of the tibia may be effectively managed with the free fibula flap. However, any alteration of limb alignment with residual bony angular deformity of the tibia must be also addressed. We describe the use of the free fibula flap in conjunction with external fixation to allow residual deformity correction and patient mobilization ambulation during healing of the free flap. METHODS: Retrospective medical record review was conducted of patients with segmental tibial defects greater than 7 cm who underwent reconstruction with fibula free flap and simple pin-bar external fixation, followed by conversion to 6-axis computer-assisted multiplanar circular ring external fixation to correct residual bony deformity. Outcomes analyses included free flap complications, return to the operating room, complications associated with the external fixation, bony union, correction of residual deformity, amputation rate, visual analog pain scales, and patient satisfaction. RESULTS: Eight patients (8 tibiae) underwent reconstruction. Mean tibial bone defect was 10.2 cm; all limbs had soft-tissue defects (mean size, 138 cm). Free fibula grafts were harvested as osteocutaneous or osteomyocutaneous flaps (average length, 12 cm). Complications included 1 delayed union and 3 (37.5%) patients readmitted for graft fracture. Ultimately, 100% of patients achieved graft union with satisfactory correction of residual limb deformity. Limb salvage rate was 100%. DISCUSSION: Management of segmental tibial bone loss utilizing initial simple external fixation and microsurgical reconstruction followed by application of computer-assisted circular external fixator may provide a reliable reconstructive protocol for posttraumatic tibial defects with residual bone malalignment.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Bibbo C, Bauder AR, Nelson J, et al. Reconstruction of Traumatic Defects of the Tibia With Free Fibula Flap and External Fixation. Ann Plast Surg. 2020. PMID: 32032114. doi:10.1097/SAP.0000000000002240

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。