文献速递颅颌面外科

黑骨MRI与三维CT在颅缝早闭术前评估中的比较

Comparison of Black Bone MRI and 3D-CT in the preoperative evaluation of patients with craniosynostosis.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2019-11-27

该研究纳入9例临床颅缝早闭患者,对比黑骨MRI(BB-MRI)与常规三维CT在术前评估颅缝和颅内压迹中的表现。两种方法均能识别所有患者的病变颅缝,评估者间信度高,但颅内压迹评估信度均低。BB-MRI可一次成像同时提供颅缝、颅内压迹及脑结构信息,有望替代电离辐射方法。

要点

  • BB-MRI与3D-CT均能识别所有颅缝早闭患者的病变颅缝。
  • 两种方法评估颅缝的信度高,但评估颅内压迹的信度均低。
  • BB-MRI可一次成像同时评估颅缝、颅内压迹及脑结构,无电离辐射。

核心结论

  • BB-MRI可作为颅缝早闭术前评估中3D-CT的替代方法。
  • BB-MRI在一次成像中同时提供颅缝、颅内压迹及脑结构信息,可替代基于电离辐射的颅骨畸形分析方法。

研究设计与样本

  • 对9例临床颅缝早闭患者同时行BB-MRI和3D-CT,由两名颅面外科医生、一名小儿神经外科医生和两名神经放射科医生评估图像。
  • 开发半自动颅骨分割算法以辅助三维可视化。

主要发现

  • 9例中6例为舟状头,1例为单侧冠状缝早闭,2例为人字缝早闭。
  • 所有患者的病变颅缝均可通过BB-MRI和3D-CT识别。
  • 颅缝评估的评估者内信度和评估者间信度均高。
  • 颅内压迹评估在两种成像方法中信度均低。

临床怎么用

  • 在颅缝早闭术前评估中,可考虑用BB-MRI替代3D-CT以避免电离辐射。
  • BB-MRI可一次成像同时评估颅缝、颅内压迹和脑结构。

局限性

  • 样本量仅9例,结论需更大样本验证。
  • 颅内压迹评估在两种方法中信度均低。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Black Bone (BB) magnetic resonance imaging (MRI) is a nonionizing imaging method and a recent alternative to computed tomography (CT) in the examination of cranial deformities. The purpose of this study was to compare BB-MRI and routine 3D-CT in the preoperative evaluation of patients with craniosynostosis. METHODS: At our center, we have routinely performed preoperative CT of the skull and brain MRI for patients with clinical suspicion of craniosynostosis. We recently changed our MRI protocol into one that includes sequences for the evaluation of both brain anatomy and skull bone and sutures by BB-MRI. A semi-automatic skull segmentation algorithm was developed to facilitate visualization. Both BB-MRI and 3D-CT were performed on 9 patients with clinical craniosynostosis, and the images were evaluated by two craniofacial surgeons, one pediatric neurosurgeon, and two neuroradiologists. RESULTS: We obtained informative 3D images using BB-MRI. Six (6/9) patients had scaphocephaly, 1 (1/9) patient had unicoronal synostosis, and 2 (2/9) patients had lambdoid synostosis. The affected synostotic sutures could be identified both by BB-MRI and by 3D-CT in all patients. Intra-rater and inter-rater reliability for rating the calvarial sutures was high. However, the reliability for rating the intracranial impressions was low by both imaging methods. CONCLUSION: BB-MRI is an alternative to 3D-CT in the preoperative evaluation of patients with craniosynostosis. BB-MRI provides information not only on cranial sutures and intracranial impressions but also on the brain structure in one imaging session. This method can replace ionizing radiation-based methods in analyzing skull deformities.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Saarikko A, Mellanen E, Kuusela L, et al. Comparison of Black Bone MRI and 3D-CT in the preoperative evaluation of patients with craniosynostosis. J Plast Reconstr Aesthet Surg. 2019. PMID: 31917189. doi:10.1016/j.bjps.2019.11.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。