自由皮瓣静脉吻合技术的Meta分析
该Meta分析纳入32项回顾性观察研究、共10,851例患者和12,769个游离皮瓣,比较静脉吻合器与手工缝合的术后静脉血栓风险。7项研究的直接比较显示吻合器组血栓风险可能降低,但估计不精确(RR 0.68,95%CI 0.39-1.19),所有研究偏倚风险高。结论认为需进一步随机试验验证。
要点
- 静脉吻合器可能降低皮瓣术后静脉血栓风险,但证据不精确。
- 纳入研究均为回顾性观察设计,偏倚风险普遍高。
- 需随机试验进一步评估吻合器尺寸不匹配对结局的影响。
核心结论
- 静脉吻合器可能降低静脉血栓风险,但需随机试验数据提高估计准确性。
- 尚需研究供受体血管尺寸不匹配及吻合器尺寸对结局的影响。
研究设计与样本
- 遵循PRISMA的系统综述与Meta分析,检索MEDLINE和Embase至2018年10月1日。
- 纳入32项回顾性观察研究,共10,851例患者、12,769个游离皮瓣。
- 主要结局为术后静脉血栓风险,次要结局为手术吻合时间。
- 偏倚风险评估采用ROBINS-I或NIH工具,推荐意见采用GRADE标准。
主要发现
- 7项研究的直接比较Meta分析显示静脉吻合器术后血栓风险降低,但估计不精确(RR 0.68,95%CI 0.39-1.19)。
- 所有纳入研究的偏倚风险 consistently 高。
关键数值与推荐
- 静脉吻合器对比手工缝合的静脉血栓风险RR 0.68(95%CI 0.39-1.19)。
临床怎么用
- 静脉吻合器可作为降低静脉血栓风险的选项,但需结合个体情况谨慎选择。
- 临床决策时应考虑当前证据偏倚风险高且估计不精确。
局限性
- 纳入研究均为回顾性观察设计,偏倚风险高。
- 静脉血栓风险的估计不精确(95%CI宽且跨1)。
- 缺乏随机试验数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Coupler devices and hand-sewn anastomosis techniques are both routinely employed for venous anastomosis in microsurgical free flap transfer. However, uncertainty remains about whether those two techniques are different in terms of risk of venous thrombosis. The aim of this review was to evaluate the quality of the evidence and quantify the difference in venous thrombosis rates in both techniques. METHOD: A Preferred Reporting Items for Systematic Reviews and Meta-Analyses compliant systematic review and meta-analysis were performed according to a previously published protocol. MEDLINE and Embase databases were searched from inception to 1 October 2018. Clinical studies using coupler devices for venous anastomoses in free tissue transfer were included. The primary outcome was post-operative venous thrombosis risk. Surgical anastomosis time was a secondary outcome. The risk of bias was assessed with the ROBINS-I or NIH tool and recommendations were made using the GRADE criteria. RESULTS: A total of 10,851 patients across 32 observational retrospective studies were included, with data available for 12,769 free flaps in breast, head and neck, limb and other reconstructions. Direct comparison meta-analysis of 7 studies showed a reduced post-operative thrombosis risk for venous coupler, although this was an imprecise estimate (RR 0.68 [95% CI 0.39-1.19]). The risk of bias was consistently high across all studies. CONCLUSION: Venous couplers may reduce the risk of venous thrombosis, but further randomised trial data are needed to improve the accuracy of this estimate. Further research should also assess size-mismatch between donor and recipient vessel, and the influence of coupler size on outcomes (PROSPERO registration ID: CRD42018110111).
引用
- Geierlehner A, Rodi T, Mosahebi A, et al. Meta-analysis of venous anastomosis techniques in free flap reconstruction. J Plast Reconstr Aesthet Surg. 2019. PMID: 31928960. doi:10.1016/j.bjps.2019.11.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。