闭合切口负压伤口治疗海绵宽度与张力卸载:实验室模型
该实验室模型研究旨在确定闭合切口负压伤口治疗(ciNPWT)中使用何种宽度的海绵能提供最大的张力卸载。在解剖模型上制作切口并以单针缝合关闭,用测力计切向施加力直至5-0缝线断裂导致伤口裂开。结果显示无ciNPWT时裂开所需峰值力最低(28.7 N),而使用3、6、9 cm宽海绵时分别为43.0、38.7、36.4 N,各组间差异有统计学意义(P<0.0001)。海绵宽度与张力卸载呈负相关,3 cm宽海绵卸载张力最多。
要点
- ciNPWT可提高切口裂开所需峰值力,最高达49.7%。
- 海绵宽度越小,张力卸载效果越好。
- 3 cm宽海绵所需的裂开峰值力最大。
核心结论
- 闭合切口负压伤口治疗可增加切口裂开所需峰值力,且海绵宽度与张力卸载呈负相关。
研究设计与样本
- 实验室模型研究,在解剖模型上制作切口并以单针缝合关闭,每种条件重复10次。
主要发现
- 无ciNPWT时裂开平均峰值力最低,为28.7 N。
- 使用3、6、9 cm宽V.A.C.海绵时平均峰值力分别为43.0、38.7、36.4 N。
- 所有试验间差异有统计学意义(P<0.0001,单因素方差分析及Tukey事后检验)。
- ciNPWT与无ciNPWT相比,裂开所需峰值力最高增加49.7%。
关键数值与推荐
- ciNPWT海绵宽度为3、6、9 cm,负压为125 mm Hg。
- 以5-0缝线断裂作为伤口裂开的判定标准。
临床怎么用
- 临床使用ciNPWT时,选择较小宽度(如3 cm)的海绵可能更有利于张力卸载。
局限性
- 本研究为实验室模型,结果需临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Closed incisional negative pressure wound therapy (ciNPWT) has become commonplace in surgery. One mechanism ciNPWT may prevent incision site complications is by off-loading tension. This study aimed to find what width sponge using ciNPWT provides the most tension off-loading.A model was designed to test tension off-loading of a wound using ciNPWT. An incision was made in an anatomy model and closed with single stitch at the central axis. Force was applied tangentially using a force gauge at a steady rate until the wound dehisced at a peak force indicated by the 5-0 suture breaking. This was repeated 10 times for the following 4 trials: no ciNPWT and ciNPWT sponges cut a 3-, 6-, and 9-cm widths with 125 mm Hg of negative pressure.The mean peak force to dehisce the wound without ciNPWT was the lowest, 28.7 N. The mean force for the ciNPWT trials was 43.0, 38.7, and 36.4 N for V.A.C. sponges of 3, 6, and 9 cm in width, respectively. There was a statically significant difference among all the trials using one-way analysis of variance with Tukey posttest analysis with a P value of less than 0.0001.Closed incisional negative pressure wound therapy was shown to increase peak force required to dehisce an incision of up to 49.7% compared with closure without. There is an inverse relationship with sponge width and tension off-loading. The smaller the sponge, the more tension is off-loaded across the incision. Closed incisional negative pressure wound therapy with a 3-cm-wide sponge required the greatest peak force for dehiscence.
引用
- Googe B, Davidson JC, Arnold PB, et al. Closed Incisional Negative Pressure Wound Therapy Sponge Width and Tension Off-Loading: A Laboratory Model. Ann Plast Surg. 2020. PMID: 31923015. doi:10.1097/SAP.0000000000002217
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。