文献速递乳房整形与再造显微修复重建

游离DIEP皮瓣应作为乳房再造质量指标吗?

Should free deep inferior epigastric artery perforator flaps be considered a quality indicator in breast reconstruction?
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2019-09-07

本文综述腹壁游离组织移植用于乳房再造的供区与皮瓣特征及并发症,指出常用命名过于简化,未充分纳入肌肉保留程度、筋膜受累、补片植入和神经解剖等变量。目前证据不足以支持将DIEP皮瓣采集作为乳房再造质量指标,因DIEP皮瓣结局未明显优于MS-TRAM皮瓣。

要点

  • 常用皮瓣命名过于简化,未充分纳入肌肉保留、筋膜受累、补片和神经解剖等变量。
  • 供区影响仍是自体乳房再造的首要原则,分类时应充分尊重皮瓣采集后遗留状态。
  • 现有证据不足以支持将DIEP皮瓣采集作为乳房再造质量指标。

核心结论

  • 目前证据不足以支持将DIEP皮瓣采集作为乳房再造的质量指标,因DIEP皮瓣结局未明显优于MS-TRAM皮瓣。

研究设计与样本

  • 综述文章,检索并分析乳房再造中腹壁游离组织移植相关文献,涵盖供区和皮瓣特征及并发症与 morbidity。

主要发现

  • 常用命名过于简化,导致肌肉保留程度、筋膜受累、补片植入和节段神经解剖等关键变量未充分纳入。
  • DIEP皮瓣与MS-TRAM皮瓣相比,结局未明显更优。

临床怎么用

  • 临床分类皮瓣时应充分尊重供区遗留状态,并纳入肌肉保留程度、筋膜受累、补片植入和神经解剖等变量。
  • 不应将DIEP皮瓣采集率作为乳房再造质量指标。

局限性

  • 综述文章,未报告系统检索策略、样本量或定量合并分析。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Over the past several decades, technical advances in breast reconstruction have resulted in the development of flaps that are aimed at progressively decreasing abdominal wall morbidity. There is, however, ongoing controversy related to the superiority of deep inferior epigastric perforator (DIEP) flaps over muscle-sparing TRAM (MS-TRAM) flaps. Hence, the question remains unanswered as to which approach should be considered the standard of care, and more importantly, whether the rate of DIEP flap utilization should be considered a quality metric in breast reconstruction. In this review article, we examine the literature pertaining to abdominal free tissue transfer in breast reconstruction from both donor site and flap characteristics as well as the resultant complications and morbidity. The impact on the donor site remains a prevailing principle for autologous breast reconstruction; thus, must be adequately respected when classifying what is left behind following flap harvest. The most commonly used nomenclature is too simplistic. This, in turn, leads to inadequate incorporation of critical variables, such as degree of muscular preservation, fascial involvement, mesh implantation, and segmental nerve anatomy. Currently, there is insufficient evidence to support DIEP flap harvest as a quality indicator in breast reconstruction, as DIEP flap outcomes are not clearly superior when compared with MS-TRAM flaps.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Tevlin R, Wan DC, Momeni A, et al. Should free deep inferior epigastric artery perforator flaps be considered a quality indicator in breast reconstruction? J Plast Reconstr Aesthet Surg. 2019. PMID: 31570216. doi:10.1016/j.bjps.2019.08.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。