文献速递乳房整形与再造美容整形

减质量假体乳房运动学初步研究

The Kinematics of Breasts Implanted With a Reduced Mass Implant: A Pilot Study.
PubMed 文献 · Aesthet Surg J · 2020-01-01

本试点研究纳入2例减质量假体隆乳者与2例乳房大小相近的自然乳房者,用电磁传感器记录站立、行走和跑步时乳头相对躯干的运动学。结果显示减质量假体者站立时乳头突度和抬高更大、行走时乳头加速度降低50%;假体置于腺体下者跑步时乳头运动学最小化。

要点

  • 减质量假体者行走时乳头加速度较自然乳房者降低50%
  • 腺体下放置减质量假体者跑步时乳头运动学最小
  • 动态活动中乳头运动学降低可能减少乳房结构负荷

核心结论

  • 腺体下放置联合减质量假体可最小化跑步时乳头运动学,可能减少乳房结构负荷、帮助减少下垂并延长手术效果持久性。

研究设计与样本

  • 试点研究纳入2例减质量假体隆乳者(术后12-15个月:术前32AA、解剖型肌下255cc B-Lite;术前32A、解剖型腺体下285cc B-Lite)和2例乳房大小与人体测量学相近的自然乳房者。
  • 用电磁传感器记录站立、行走和跑步时乳头与躯干位置数据,计算乳头相对躯干的运动学。

主要发现

  • 两例B-Lite参与者站立时乳头突度和抬高均大于自然乳房对照。
  • 两例B-Lite参与者行走时乳头加速度较自然乳房对照降低50%。
  • 跑步时B-Lite腺体下参与者乳头运动学低于其自然对照,且行走和跑步时低于B-Lite肌下参与者。

临床怎么用

  • 对于关注动态活动中乳房稳定性的隆乳者,可考虑腺体下放置减质量假体以最小化跑步时乳头运动学。

局限性

  • 本研究为试点研究,仅纳入2例减质量假体隆乳者和2例自然乳房对照,样本量小。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Breast implants may increase breast skin tension and interact with surrounding tissues to alter breast position and motion during dynamic activity. Reducing implant mass and changing implant location (submuscular/subglandular) may also affect breast kinematics and the subsequent loads on breast structures. OBJECTIVES: The aim of this pilot study was to describe the kinematics of breasts augmented with reduced-mass implants during standing, walking, and running, compared with natural breasts, and to provide insight into how implant location (submuscular/subglandular) alters breast kinematics. METHODS: Two breast augmentation participants (12-15 months postsurgery: 32AA presurgery, anatomical submuscular 255 cc B-Lite reduced-mass implant; 32A presurgery, anatomical subglandular 285 cc B-Lite reduced-mass implant) and 2 natural-breasted participants of similar breast size and anthropometrics were recruited. Nipple and torso positional data were recorded with electromagnetic sensors during standing, walking, and running. Nipple kinematics relative to the torso were calculated. RESULTS: The B-Lite participants both displayed greater nipple projection and elevation during standing and a 50% reduction in nipple acceleration during walking, when compared with their natural counterparts. During running, the B-Lite subglandular participant displayed decreased nipple kinematics compared with her natural counterpart and lower nipple kinematics compared with the B-Lite submuscular participant during walking and running. CONCLUSIONS: A combination of implant location (subglandular) and reduced mass minimized nipple kinematics during running. Reducing nipple kinematics during dynamic activity may decrease the loading on breast structures, helping to decrease ptosis and increase the longevity of procedure outcomes.

来源:Aesthet Surg J,查看原文。版权归原作者所有。

引用

  1. Norris M, Jones M, Mills C, et al. The Kinematics of Breasts Implanted With a Reduced Mass Implant: A Pilot Study. Aesthet Surg J. 2020. PMID: 31504162. doi:10.1093/asj/sjz239

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。