文献速递显微修复重建创面修复

内侧腓肠动脉穿支蒂螺旋桨皮瓣修复小腿中段缺损

The medial sural artery perforator pedicled propeller flap for coverage of middle-third leg defects.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2019-09-07

该回顾性病例系列报告了7年间采用带蒂内侧腓肠动脉穿支(MSAP)皮瓣修复下肢缺损的经验。11例顺行蒂皮瓣全部成活,平均蒂长11.3 cm,双 pivoting(n=4)后平均弧长29 cm;3例逆行蒂皮瓣中2例达到创面覆盖、1例完全坏死。作者认为螺旋桨皮瓣设计可将顺行蒂MSAP皮瓣的覆盖范围延伸至小腿中段前侧,但逆行蒂皮瓣的可靠性尚需进一步研究。

要点

  • 螺旋桨皮瓣设计可将顺行蒂MSAP皮瓣覆盖范围延伸至小腿中段前侧缺损。
  • 11例顺行蒂MSAP皮瓣全部成活,平均蒂长11.3 cm。
  • 逆行蒂MSAP皮瓣初步经验结果不一,3例中1例完全坏死。

核心结论

  • 「带蒂螺旋桨皮瓣」设计可将顺行蒂MSAP皮瓣的覆盖范围延伸至小腿中段前侧缺损。
  • 逆行蒂MSAP皮瓣的初步经验结果不一,需进一步研究其可靠性。

研究设计与样本

  • 回顾性病例系列,收集7年间所有接受带蒂MSAP皮瓣下肢重建的患者资料并回顾手术结局。
  • 对小腿前侧中段缺损采用「带蒂螺旋桨皮瓣」设计;对超出顺行蒂MSAP皮瓣覆盖范围的更远端缺损采用逆行蒂MSAP皮瓣。

主要发现

  • 11例顺行蒂MSAP皮瓣用于膝至小腿中段的缺损,病因包括创伤、慢性溃疡和皮肤恶性肿瘤,全部成活并获良好结局。
  • 顺行蒂MSAP皮瓣平均蒂长11.3 cm(范围7–18 cm),双 pivoting(n=4)后平均弧长29 cm(范围22–36 cm)。
  • 3例逆行蒂MSAP皮瓣中2例达到创面覆盖目标,1例完全皮瓣坏死。

临床怎么用

  • 小腿中段前侧缺损可考虑采用带蒂螺旋桨皮瓣设计的顺行蒂MSAP皮瓣以延伸覆盖范围。
  • 逆行蒂MSAP皮瓣可靠性尚不明确,临床应用需谨慎评估。

局限性

  • 为回顾性病例系列,样本量小(顺行蒂11例、逆行蒂3例)。
  • 逆行蒂MSAP皮瓣结果不一,作者指出需进一步研究其可靠性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Pedicled medial sural artery perforator (MSAP) flap has been described primarily for the coverage of knee and proximal-third leg defects. The technique for reaching the middle third and its use as a retrograde-flow flap were never demonstrated with clarity. This retrospective case-series aimed to report the author's experience in these regards. PATIENTS AND METHODS: Details of all patients who underwent pedicled MSAP flap for lower limb reconstruction over a 7-year period were collected. Surgical outcomes were examined retrospectively. For defects in the anterior middle third of the leg, the "pedicled propeller flap" design was utilized. To determine more distal defects beyond the reach of the anterograde-flow MSAP flap, retrograde-flow pedicled MSAP flaps were used. RESULTS: Eleven anterograde-flow pedicled MSAP flaps were used for defects ranging from the knee to the middle third of the leg. The etiologies of defects included trauma, chronic ulcer, and skin malignancy. All 11 anterograde pedicled MSAP flaps survived and achieved good outcomes. The mean pedicle length was 11.3 cm (range 7-18 cm), and the mean arc length after double pivoting (n = 4) was 29 cm (range 22-36 cm). Of three retrograde-flow pedicled MSAP flaps, two achieved the goal of wound coverage and one suffered complete flap loss. CONCLUSION: The "pedicled propeller flap" design extends the reach of the anterograde-flow pedicled MSAP flap as far as the middle-third anterior leg defects. Our preliminary experience with retrograde-flow MSAP flap has mixed results. Further studies are required to examine its reliability.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Tee R, Jeng SF, Chen CC, et al. The medial sural artery perforator pedicled propeller flap for coverage of middle-third leg defects. J Plast Reconstr Aesthet Surg. 2019. PMID: 31562028. doi:10.1016/j.bjps.2019.08.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。