文献速递颅颌面外科

定制三维打印间隔器在正颌手术中辅助骨定位以矫正和预防面部不对称

Customized Three-Dimensional Printing Spacers for Bone Positioning in Orthognathic Surgery for Correction and Prevention of Facial Asymmetry.
PubMed 文献 · Plast Reconstr Surg · 2019-01-01

本研究前瞻性纳入面部不对称患者,利用计算机辅助设计与三维打印制作个性化「间隔器」,在正颌手术中辅助骨块定位与固定。12例患者共使用19个间隔器,术后VAS评分和面部表面积差异指数均显著改善,无相关手术并发症,患者均满意。

要点

  • 定制三维打印间隔器可辅助正颌手术中骨块的精准定位与固定。
  • 术后面部对称性主观VAS评分从4.83升至7.14(p=0.018)。
  • 面部表面积差异指数从0.95升至0.98,不对称矫正显著(p=0.009)。

核心结论

  • 定制三维打印间隔器有助于正颌手术中实现手术精准度,以矫正和预防面部不对称。

研究设计与样本

  • 前瞻性研究,连续纳入面部不对称患者,共12例,使用19个间隔器用于Le Fort I和下颌升支骨段。

主要发现

  • 间隔器在骨固定过程中应用良好。
  • 术前和术后平均VAS评分分别为4.83和7.14,面部对称性改善有统计学意义(p=0.018)。
  • 术前和术后平均面部表面积差异指数分别为0.95和0.98,不对称矫正显著(p=0.009)。
  • 无相关手术并发症,所有患者对face不对称和咬合不正的矫正满意。

临床怎么用

  • 对于面部不对称的正颌手术患者,可基于三维手术计划设计并打印个性化间隔器,辅助术中骨块定位与固定。

局限性

  • 证据等级为治疗性IV级。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Orthognathic surgery is a powerful tool for correction of facial asymmetry and malocclusion. The goal is to achieve good dental function and facial aesthetics. Three-dimensional simulation is used for surgical planning, and bone gaps could be created to achieve facial balance. In this study, customized "spacers" were made using computer-aided design and three-dimensional printing for guides for use during surgery. With the final three-dimensional plan, the skull images were exported to 3-Matic software, where spacers were designed according to the bone gaps. Three-dimensionally-printed spacers were made and used to facilitate positioning and fixation. Consecutive patients with facial asymmetry were recruited in this prospective study. The postoperative outcome was assessed using a visual analogue scale and the three-dimensional facial surface area discrepancy index for subjective and objective evaluation. There were 12 patients and a total of 19 spacers for the Le Fort I and mandibular ramus segments. The spacers worked nicely during the bone fixation process. Mean preoperative and postoperative visual analogue scale scores were 4.83 and 7.14, with a statistically significant improvement for facial symmetry (p = 0.018). Mean preoperative and postoperative facial surface area discrepancy index was 0.95 and 0.98, and the correction of asymmetry was significant (p = 0.009). There were no related surgical complications. All patients were satisfied with the correction of facial asymmetry and malocclusion. The custom-made, three-dimensionally-printed spacers help to achieve surgical precision to correct and prevent facial asymmetry in orthognathic surgery. CLINICAL QUESTION/LEVEL OF EVIDENCE:: Therapeutic, IV.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Dumrongwongsiri S, Lin HH, Niu LS, et al. Customized Three-Dimensional Printing Spacers for Bone Positioning in Orthognathic Surgery for Correction and Prevention of Facial Asymmetry. Plast Reconstr Surg. 2019. PMID: 31348355. doi:10.1097/PRS.0000000000005858

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。