烧伤患者碳青霉烯耐药鲍曼不动杆菌的系统综述与荟萃分析
该研究系统综述了烧伤患者碳青霉烯耐药鲍曼不动杆菌(CRAB)的抗菌药物敏感性模式及耐药决定因素。纳入17篇文献、1226株CRAB,多数来自伊朗、烧伤创面。荟萃分析显示OXA型碳青霉烯酶为主要耐药机制(53.2%),米诺环素(69.5%)和黏菌素(99.9%)敏感性仍高。
要点
- OXA型碳青霉烯酶是烧伤患者CRAB低碳青霉烯敏感性的主要机制(53.2%)。
- 米诺环素和黏菌素对CRAB保持较高敏感性(69.5%和99.9%)。
- 多数研究未区分感染与定植,需高质量监测以指导干预。
核心结论
- 烧伤患者CRAB耐药以OXA型碳青霉烯酶为主,米诺环素和黏菌素敏感性高。
- 需全球高质量监测项目以设计有效干预措施控制烧伤病房CRAB感染。
研究设计与样本
- 系统综述与荟萃分析,遵循PRISMA声明,检索PUBMED/MEDLINE、Scopus、SciELO、BVS和Cochrane Library。
- 纳入17篇文献,评估1226株烧伤患者分离的CRAB,酶学耐药机制数据采用随机效应模型荟萃分析。
主要发现
- OXA型碳青霉烯酶占53.2%(95%CI=60-80.0%,I2=86.0%),MBL占30.2%(95%CI=11-42.0%,I2=93.0%),KPC占16.6%(95%CI=5-63.0%,I2=88.0%)。
- 多数菌株携带blaOXA-23-like(12/17;70.6%)或blaOXA-24/40-like(12/17;35.3%)基因。
- 米诺环素敏感性69.5%,黏菌素敏感性99.9%,不受碳青霉烯耐药影响。
关键数值与推荐
- OXA型碳青霉烯酶:53.2%(95%CI=60-80.0%,I2=86.0%)。
- MBL:30.2%(95%CI=11-42.0%,I2=93.0%)。
- KPC:16.6%(95%CI=5-63.0%,I2=88.0%)。
- 米诺环素敏感性69.5%,黏菌素敏感性99.9%。
临床怎么用
- 烧伤患者CRAB经验性治疗可考虑米诺环素或黏菌素,但需结合本地药敏。
- 应加强烧伤病房CRAB耐药监测,区分感染与定植以指导抗菌药物使用。
局限性
- 多数研究来自伊朗(12/17;70.6%),代表性有限。
- 超过半数研究(10/17;58.8%)未区分感染与定植。
- 纳入研究间异质性高(I2最高达93.0%)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: In this study, we aimed reviewed the data about the patterns of antimicrobial susceptibility and resistance determinants among carbapenem-resistant Acinetobacter baumannii (CRAB) from patients with burn injury. METHODS: A systematic review was conducted using the PRISMA statement in PUBMED/MEDLINE, Scopus, Scientific Electronic Library Online (SciELO), Biblioteca Virtual de Saúde (BVS) and Cochrane Library. The data referring to enzymatic resistance mechanisms were evaluated by meta-analyses according to random effect. RESULTS: 17 articles that evaluated 1226 CRAB recovered from patients with burn injury were included in study. The majority of studies are from Iran (12/17; 70.6%), published in 2016 (6/17; 35.3%) and showed prospective design (15/17; 88.2%). The samples were obtained mainly from burn wounds (14/17; 82.3%) and more than half of the studies did not identify if the isolates originated from infected or colonized patients (10/17; 58.8%). Second the meta-analyses, OXA-type carbapenemase was the main mechanism involved in low susceptibility to carbapenems (53.2%; 95% CI = 60, 80.0%, I2 = 86.0%), followed by metallo-β-lactamases (MBL) (30.2%; 95% CI = 11, 42.0%, I2 = 93.0%), and Klebsiella pneumoniae carbapenemase (KPC) (16.6%; 95% CI = 5, 63.0%, I2 = 88.0%). The majority of strains harbored blaOXA-23-like (12/17; 70.6%) or blaOXA-24/40-like (12/17; 35.3%) genes. The studies included showed that minocycline (69.5%) and colistin (99.9%) susceptibility remains high and is not impacted by carbapenem resistance in these isolates. CONCLUSIONS: The results summarized in this review indicate the importance of a high-quality surveillance program to design suitable and effective interventions to control CRAB infection in burn units worldwide.
引用
- Lima WG, Silva Alves GC, Sanches C, et al. Carbapenem-resistant Acinetobacter baumannii in patients with burn injury: A systematic review and meta-analysis. Burns. 2019. PMID: 31351820. doi:10.1016/j.burns.2019.07.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。