三维立体摄影测量作为临床常规瘢痕体积评估的可靠方法

Incorporation of 3D stereophotogrammetry as a reliable method for assessing scar volume in standard clinical practice.
PubMed 文献 · Burns · 2019-06-15

该研究通过创建瘢痕模型并用三维相机拍摄,将三维图像分析的体积测量与物理测量比较,并在烧伤患者增生性瘢痕中评估观察者间一致性。结果显示两种体积计算方法无显著差异(p=0.89),观察者间相关系数为0.92,患者瘢痕体积的组内相关系数为0.998,每例患者拍摄耗时2至6分钟,表明三维立体摄影测量可可靠测量瘢痕体积并适合临床常规使用。

要点

  • 三维立体摄影测量与物理测量瘢痕模型体积无显著差异(p=0.89)。
  • 观察者间瘢痕模型体积测量相关系数为0.92,患者瘢痕体积组内相关系数为0.998。
  • 每例患者三维拍摄耗时2至6分钟,适合纳入临床常规。

核心结论

  • 三维立体摄影测量是可靠测量瘢痕体积的有效方法,可用于客观评估瘢痕治疗疗效及追踪瘢痕发展与消退。

研究设计与样本

  • 研究创建瘢痕模型并用三维相机拍摄,将三维图像分析体积与物理测量比较,并在烧伤患者增生性瘢痕中评估观察者间一致性,同时记录患者拍摄时间。

主要发现

  • 两种体积计算方法无显著差异(p=0.89),差异图显示两种方法一致。
  • 两名独立观察者测量瘢痕模型体积的相关系数为0.92。
  • 烧伤患者增生性瘢痕三维图像测量的组内相关系数为0.998。
  • 每例患者拍摄三维照片耗时2至6分钟。

临床怎么用

  • 可将三维立体摄影测量纳入临床常规,用于客观测量瘢痕体积并追踪瘢痕治疗疗效。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Significant disfigurement and dysfunction is caused by hypertrophic scarring, a prevalent complication of burn wounds. A lack of objective tools in the assessment of scar parameters makes evaluation of scar treatment modalities difficult. 3D stereophotogrammetry, obtaining measurements from 3D photographs, represents a method to quantitate scar volume, and a 3D camera may have use in clinical practice. To validate this method, scar models were created and photographed with a 3D camera. Measurements from 3D image analysis of these scar models were compared to physical measurements of scar model volume. Reliability of 3D image analysis was assessed with both scar models and burn patient scars. Measurements of scar models by two independent observers were compared to determine inter-rater reliability, and measurements from 3D images of burn patient hypertrophic scars were compared to determine the consistency of the method between observers. The time taken for patient photography was recorded. No significant differences were found between the two methods of volume calculation (p = 0.89), and a plot of the differences showed agreement between the methods. The correlation coefficient between the two observers' measurements of scar model volume was 0.92, and the intra-class correlation coefficient for patient scar volume was 0.998, showing good reliability. The time required to capture 3D photographs ranged from 2 to 6 min per patient, showing the potential for this tool to be efficiently incorporated into clinical practice. 3D stereophotogrammetry is a valid method to reliably measure scar volume and may be used to objectively measure efficacy of scar treatment modalities to track scar development and resolution.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Peake M, Pan K, Rotatori RM, et al. Incorporation of 3D stereophotogrammetry as a reliable method for assessing scar volume in standard clinical practice. Burns. 2019. PMID: 31208769. doi:10.1016/j.burns.2019.05.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。