本研究回顾2013至2018年43例接受血管化空肠移植重建咽食管患者的临床资料,采用外置肠系膜作为监测标志,护士术后每2小时用便携式多普勒超声监测7天。结果显示40例可监测患者中39例术后顺利,1例因无信号及无出血行血管吻合翻修后移植物获救,监测瓣无感染或增生性瘢痕。

要点

  • 外置肠系膜监测法操作简便,便于临床直接观察和多普勒监测。
  • 43例中40例可应用多普勒监测,39例术后顺利。
  • 1例术后即刻无多普勒信号且针刺无出血,吻合翻修后移植物获救。

核心结论

  • 外置肠系膜监测瓣可行临床监测,且仅管理肠系膜监测瓣比空肠监测瓣更简便。

研究设计与样本

  • 回顾性研究,2013至2018年共43例患者接受血管化空肠移植重建喉咽切除术缺损,使用外置肠系膜监测法。
  • 患者包括39名男性和4名女性,年龄40至80岁,平均66.6岁。

主要发现

  • 3例术中便携式多普勒超声在外置肠系膜监测瓣上信号较弱,无法应用多普勒监测。
  • 其余40例使用多普勒监测的患者中,39例术后顺利。
  • 1例术后即刻监测段无多普勒信号且针刺无出血,行血管吻合翻修,最终移植物获救。
  • 监测瓣无感染病例,监测瓣切除部位无增生性瘢痕病例。

关键数值与推荐

  • 护理人员术后7天内每2小时使用便携式多普勒超声监测外置肠系膜。

临床怎么用

  • 对于血管化空肠移植重建,可采用外置肠系膜作为监测标志,便于护理人员每2小时多普勒监测和临床观察。
  • 若术后即刻监测段无多普勒信号且针刺无出血,应考虑血管吻合问题并及时手术探查。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The use of externalized jejunal monitoring flaps for jejunum transfers could be facilitative for the direct clinical assessment. Although this monitoring method would seem to be highly reliable, we modified this method and used mesentery only as a monitor to make it easy to manage the monitor more. METHODS: Between 2013 and 2018, 43 patients underwent vascularized jejunum transfer for reconstruction of laryngopharyngectomy using the externalized mesentery monitor. There were 39 men and 4 women, and patient ages ranged from 40 to 80 years (average, 66.6 years). The nursing staff monitored the externalized mesentery by using handheld Doppler ultrasonography every 2 hours for 7 days after surgery. RESULTS: Three patients had rather weak signal of handheld Doppler ultrasonography on the externalized mesentery monitors during operation, and handheld Doppler ultrasonography could not be applied. Of the remaining 40 patients using the externalized mesentery monitor with handheld Doppler ultrasonography, 39 had an uncomplicated postoperative period. In 1 patient, no signal of Doppler ultrasonography and lack of bleeding by pin prick from the monitor segment were noted in the immediate postoperative period, and revision of the vascular anastomosis was performed. Finally, the graft was salvaged. There was no case of infection in the monitoring flap or hypertrophic scar at the resected part of the flap. CONCLUSIONS: Using the externalized mesentery monitoring flaps, clinical monitoring by examining the exteriorized monitoring flap is possible, and only mesentery monitors were managed easily compared with jejunum monitoring flaps.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Arata J, Suzuki M, Marukawa Y, et al. Externalized Mesentery Monitoring of Vascularized Jejunum Transfers. Ann Plast Surg. 2019. PMID: 31232801. doi:10.1097/SAP.0000000000001888