文献速递烧伤创面修复

激光散斑对比成像评估烧伤的观察者间可靠性

Interobserver reliability of laser speckle contrast imaging in the assessment of burns.
PubMed 文献 · Burns · 2019-06-21

结果显示灌注值和灌注趋势的观察者间ICC为0.96,烧伤深度评估ICC为0.53,LSCI推荐意见ICC为0.95。结论表明观察者可可靠识别相同ROI,灌注测量不依赖经验,LSCI推荐意见比深度评估更准确。

要点

  • 灌注值和灌注趋势的观察者间ICC达0.96,测量可靠且不依赖烧伤经验
  • 烧伤深度评估ICC仅0.53,丰富烧伤经验未进一步改善深度判断
  • LSCI推荐意见ICC为0.95,各专业组均较深度评估更准确

核心结论

  • 观察者可可靠识别相同ROI,获得不依赖观察者的灌注测量,与烧伤经验无关。
  • 丰富烧伤经验未进一步改善烧伤深度评估。
  • LSCI推荐意见在所有专业组中均更准确,引入LSCI测量可能改善烧伤早期评估。

主要发现

  • 所有观察者间灌注值和灌注趋势的ICC为0.96(95% CI 0.91-0.99)。
  • 所有观察者烧伤深度评估的ICC为0.53(95% CI 0.31-0.80),准确度为0.53(加权kappa)。
  • 所有观察者生成的LSCI推荐意见ICC为0.95(95% CI 0.90-0.99)。

临床怎么用

  • LSCI灌注测量可在不同经验水平的观察者间可靠重复,适合用于烧伤早期评估。
  • 基于灌注趋势的LSCI推荐意见比单纯临床经验判断烧伤深度更准确。

局限性

  • 观察者均无LSCI经验,可能影响结果外推。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Laser speckle contrast imaging (LSCI) is an emerging technique for the assessment of burns in humans and interobserver differences have not been studied. The aim of this study was to compare assessments of perfusion images by different professional groups regarding (i) perfusion values and (ii) burn depth assessment. METHODS: Twelve observers without LSCI experience were included. The observers were evenly recruited from three professional groups: plastic surgeons with experience in assessing burns, nurses with experience in treating burns, and junior doctors with limited experience of burns. Ten cases were included. Each case consisted of one digital photo of the burn with a pre-marked region of interest (ROI) and two unmarked perfusion images of the same area. The first and the second perfusion image was from 24h and 72-96h after injury, respectively. The perfusion values from both perfusion images were used to generate a LSCI recommendation based on the perfusion trend (the derivative between the two perfusion values). As a last step, each observer was asked to estimate the burn depth using their clinical experience and all available information. Intraclass correlation (ICC) was calculated between the different professional groups and among all observers. RESULTS: Perfusion values and perfusion trends between all observers had an ICC of 0.96 (95% CI 0.91-0.99). Burn depth assessment by all observers yielded an ICC of 0.53 (95% CI: 0.31-0.80) and an accuracy of 0.53 (weighted kappa). LSCI recommendations generated by all observers had an ICC of 0.95 (95% CI: 0.90-0.99). CONCLUSION: Observers can reliably identify the same ROI, which results in observer-independent perfusion measurements, irrespective of burn experience. Extensive burn experience did not further improve burn depth assessment. The LSCI recommendation was more accurate in all professional groups. Introducing LSCI measurements would be likely improve early assessment of burns.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Mirdell R, Farnebo S, Sjöberg F, et al. Interobserver reliability of laser speckle contrast imaging in the assessment of burns. Burns. 2019. PMID: 31230800. doi:10.1016/j.burns.2019.01.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。