文献速递颅颌面外科创面修复

单缝颅缝早闭术后颅骨缺损的长期特征

Long-Term Characterization of Cranial Defects After Surgical Correction for Single-Suture Craniosynostosis.
PubMed 文献 · Ann Plast Surg · 2019-01-01

本研究从颅面异常档案库调取单缝颅缝早闭患儿颅顶重建术后1年及长期CT,用自制软件追踪74处大于1 cm的颅骨缺损,评估其面积与圆形度变化。结果显示缺损平均面积从3.27 cm降至1.71 cm,平均缩小55.06%,顶区缩小68.4%显著优于额顶区43.7%(P=0.001),蒙特卡洛模拟提示初始大于9 cm的缺损不足10%可闭合至2.5 cm以下。

要点

  • 颅顶重建术后1年,74处缺损平均缩小55.06%。
  • 顶区缺损缩小68.4%,显著优于额顶区43.7%(P=0.001)。
  • 初始大于9 cm的缺损多数1年后仍大于2.5 cm。

核心结论

  • 颅顶重建术后大多数大于1 cm的颅骨缺损会部分缩小,但初始大于9 cm者长期多仍大于2.5 cm,且额顶区闭合慢于顶区。

研究设计与样本

  • 回顾性队列研究,从颅面异常档案库调取单缝颅缝早闭颅顶重建术后1年及长期CT,分析74处大于1 cm的缺损,并用蒙特卡洛模拟评估初始缺损大小对闭合率的影响。

主要发现

  • 74处缺损初始平均面积为3.27±3.40 cm,最终平均面积为1.71±2.54 cm。
  • 缺损面积平均缩小55.06%±28.99%。
  • 顶区缺损缩小68.4%,额顶区缩小43.7%,差异有统计学意义(P=0.001)。
  • 蒙特卡洛模拟提示初始大于9 cm的缺损不足10%可闭合至2.5 cm或以下。

关键数值与推荐

  • 缺损纳入标准为大于1 cm,并追踪颅骨位置、表面积与圆形度。
  • 初始大于9 cm的缺损中不足10%可闭合至2.5 cm或以下。

临床怎么用

  • 可用该验证方法测量颅骨缺损,辅助判断哪些缺损会缩小至可接受大小、哪些需再次颅骨成形。
  • 对额顶区较大缺损应更早考虑再次重建,因该区域闭合较顶区慢。

局限性

  • 原文未报告样本量、随访时长及混杂因素控制等局限性信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Craniosynostosis is typically corrected surgically within the first year of life through cranial vault reconstruction. These procedures often leave open calvarial defects at the time of surgery, which are anticipated to close over time in a large proportion of cases. However, residual calvarial defects may result as long-term sequelae from cranial vault remodeling. When larger defects are present, they may necessitate further reconstruction for closure.Better understanding of the calvarial osseous healing process may help to identify which defects will resolve or shrink to acceptable size and which will require further surgery. Our study aims to assess the long-term changes in defect size after cranial vault reconstruction for craniosynostosis. METHODS: One-year postoperative and long-term computed tomography scans were retrieved from the craniofacial anomalies archive. Analysis used custom software. All defects above the size of 1 cm were analyzed and tracked for calvarial location, surface area, and circularity. Monte Carlo simulation was performed to model the effect of initial defect size on the rate of defect closure. RESULTS: We analyzed a total of 74 defects. The mean ± SD initial defect surface area was 3.27 ± 3.40 cm. The mean ± SD final defect surface area was 1.71 ± 2.54 cm. The mean ± SD percent decrease was 55.06% ± 28.99%. There was a significant difference in the percentage decrease of defects in the parietal and frontoparietal locations: 68.4% and 43.7%, respectively (P = 0.001). Monte Carlo simulation results suggest that less than 10% of defects above the size of 9 cm will close to the size of 2.5 cm or less. CONCLUSIONS: We describe and make available a novel validated method of measuring cranial defects. We find that the large majority of initial defects greater than 9 cm remain at least 1 in in size (2.5 cm) 1 year postoperatively. In addition, there appear to be regional differences in closure rates across the cranium, with frontoparietal defects closing more slowly than those in the parietal region. This information will aid surgeons in the decision-making process regarding cranioplasty after craniosynostosis correction.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Skolnick GB, Murthy S, Patel KB, et al. Long-Term Characterization of Cranial Defects After Surgical Correction for Single-Suture Craniosynostosis. Ann Plast Surg. 2019. PMID: 31082848. doi:10.1097/SAP.0000000000001906

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。