文献速递乳房整形与再造显微修复重建

TRAM皮瓣肌肉体积的长期系列测量:Eclipse治疗计划系统应用

Long-Term Serial Measurement of Muscle Volume in TRAM Flaps Using the Eclipse Treatment Planning System.
PubMed 文献 · Plast Reconstr Surg · 2019-01-01

本研究回顾性纳入35例单侧即刻乳房重建的带蒂TRAM皮瓣患者,利用Eclipse治疗计划系统对连续三次CT扫描进行肌肉体积分割测量。结果显示皮瓣侧腹直肌体积比在15、30、51个月分别为27.1%、22.1%、19.8%,外推最终稳定于19.4%,而对侧肌肉体积无显著变化。结论认为TRAM皮瓣肌肉在前15个月丢失超过70%体积,最终降至原体积约20%。

要点

  • TRAM皮瓣肌肉在前15个月体积丢失超过70%。
  • 皮瓣侧肌肉体积最终稳定于原体积约20%。
  • 对侧腹直肌体积随时间无显著变化。

核心结论

  • TRAM皮瓣肌肉在前15个月丢失超过70%体积,最终降至原体积约20%。
  • Eclipse治疗计划系统可用于回顾性测量基于CT或MRI图像的多种重建术后体积。

研究设计与样本

  • 纳入标准为完成三次系列随访CT扫描且无复发和/或放疗史,共35例符合要求(期间共451例接受TRAM皮瓣手术)。
  • 使用Eclipse软件对CT图像进行分割和三维重建,计算带蒂腹直肌肌肉体积,以对侧作为对照。

主要发现

  • 皮瓣侧腹直肌肌肉体积比在15、30、51个月分别为27.1%、22.1%、19.8%。
  • 外推体积比最终收敛于19.4%。
  • 对侧肌肉体积随时间无显著变化。

关键数值与推荐

  • 皮瓣侧腹直肌肌肉体积比:15个月27.1%,30个月22.1%,51个月19.8%,外推最终19.4%。
  • 证据等级:治疗性,IV级。

临床怎么用

  • 临床可参考TRAM皮瓣肌肉体积长期显著丢失的规律,用于术前告知和术后评估。
  • Eclipse系统可回顾性用于CT或MRI图像上的重建术后体积测量。

局限性

  • 回顾性研究,样本量有限(35例符合纳入标准)。
  • 仅纳入完成三次CT随访且无复发或放疗史的患者,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Muscle flaps used in reconstructive surgery are known to lose volume over time because of denervation and disuse atrophy. However, there is currently no agreement on a quantitative approach to evaluating volume changes. Here, long-term serial measurement of muscle volume in transverse rectus abdominis musculocutaneous (TRAM) flap breast reconstruction has been conducted using the Eclipse treatment planning system. METHODS: This was a retrospective review of the medical records of patients who underwent unilateral immediate breast reconstruction using a pedicled TRAM flap between January of 2004 and December of 2007. Patients who completed three serial follow-up computed tomographic scans and did not have history of recurrence and/or radiation therapy were included. Eclipse software was used for segmentation and three-dimensional reconstruction of the computed tomographic images; the volume of the pedicled rectus abdominis muscle was calculated, and the contralateral side served as the control. RESULTS: Among 451 patients undergoing TRAM flap surgery during the study period, 35 met the inclusion requirements. Serial measurement of rectus abdominis muscle volume of the flap showed a mean volume ratio of 27.1 percent, 22.1 percent, and 19.8 percent at 15, 30, and 51 months, respectively. The extrapolated volume ratio finally converged at 19.4 percent. Contralateral muscle volume did not change significantly over time. CONCLUSIONS: The muscle of a TRAM flap loses more than 70 percent of its volume in the first 15 months, ultimately reducing to approximately 20 percent of its original size. Eclipse can be used retrospectively for volume measurement after a variety of reconstructive procedures using computed tomographic or magnetic resonance images. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Han WY, Lee S, Kim EK, et al. Long-Term Serial Measurement of Muscle Volume in TRAM Flaps Using the Eclipse Treatment Planning System. Plast Reconstr Surg. 2019. PMID: 31136466. doi:10.1097/PRS.0000000000005609

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。