文献速递显微修复重建

流水线作业系统用于多发性淋巴管静脉吻合术

Line production system for multiple lymphaticovenular anastomoses.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2019-04-11

本研究比较流水线作业系统(LPS)与传统双显微镜(DM)系统在多发性淋巴管静脉吻合术(LVA)中的效果。LPS由新手显微外科医生用放大镜解剖淋巴管、专家用显微镜完成吻合。结果显示LPS组每小时LVA数量和成功数均显著高于DM组,淋巴水肿改善率也更高,且所需显微镜和显微外科医生更少、手术时间更短。

要点

  • LPS可提高每小时LVA数量与成功数,并改善淋巴水肿。
  • LPS所需显微镜和显微外科医生更少,手术时间更短。
  • 放大镜下淋巴管检出率平均81%±15.60%,管径0.44±0.12 mm。

核心结论

  • 使用LPS可增加LVA的数量和质量,进一步改善淋巴水肿,同时减少显微镜和显微外科医生需求并缩短手术时间。

研究设计与样本

  • 比较LPS组与DM(对照)组的临床研究;LPS组由新手显微外科医生用放大镜解剖淋巴管、专家用显微镜完成LVA,DM组均由医生用显微镜完成LVA。

主要发现

  • LPS组淋巴管检出率平均81%±15.60%,检出淋巴管平均管径0.44±0.12 mm。
  • LPS组每小时LVA数量显著高于DM组(2.15±0.20 vs. 1.38±0.17;p<0.01)。
  • LPS组每小时成功LVA数量显著高于DM组(2.08±0.22 vs. 0.84±0.14;P<0.01)。
  • LPS组LEL指数平均改善率显著高于DM组(9.36±1.85 vs. 6.93±1.73;P<0.01)。

临床怎么用

  • 在显微镜和显微外科医生资源有限时,可采用LPS由新手用放大镜解剖淋巴管、专家用显微镜完成吻合,以提高多发性LVA的效率和质量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: A drawback of multiple lymphaticovenular anastomoses (LVAs) is the need for at least two microsurgeons and the same number of microscopes. In practice, many hospitals find it difficult to access such resources. We have developed a novel line production system (LPS) to address this problem. We assessed whether or not the LPS is better than the conventional dual microscope (DM) system when performing multiple LVAs. METHODS: An LPS group, wherein a novice microsurgeon used loupes to dissect lymphatics and an expert microsurgeon used a microscope to perform the LVAs, and a DM (control) group, wherein the surgeons used microscopes to perform the LVAs. We recorded the lymphatic detection rate through the loupes and the diameter of the detected lymphatics. We also investigated the impact of using the LPS by comparing the number and quality of LVAs and improvement in lymphedema between the study groups. RESULTS: The mean lymphatic detection rate was 81%±15.60%, and the mean size of lymphatics was 0.44 ± 0.12 mm in the LPS. The number of LVAs/h in LPS was significantly higher than that in DM (2.15 ± 0.20 vs. 1.38 ± 0.17; p < 0.01). The number of successful LVAs/h in LPS was significantly higher than that in the DM (2.08 ± 0.22 vs. 0.84 ± 0.14; P < 0.01). Mean rate of improvement in LEL index was significantly higher than that in DM (9.36 ± 1.85 vs. 6.93 ± 1.73; P < 0.01). DISCUSSION: The number and quality of the LVAs increase using the LPS, which leads to further improvement in lymphedema, with fewer microscopes and microsurgeons and a shorter operating time.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Yoshida S, Koshima I, Imai H, et al. Line production system for multiple lymphaticovenular anastomoses. J Plast Reconstr Aesthet Surg. 2019. PMID: 31056432. doi:10.1016/j.bjps.2019.03.038

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。