文献速递烧伤瘢痕与激光

2940nm铒激光点阵消融改善烧伤增生性瘢痕的客观测量研究

Treating Hypertrophic Burn Scar With 2940-nm Er:YAG Laser Fractional Ablation Improves Scar Characteristics as Measured by Noninvasive Technology.
PubMed 文献 · J Burn Care Res · 2019-01-01

混合模型重复测量分析显示治疗组与对照组整体比较无显著差异,但治疗组瘢痕在黏弹性变形、弹性变形、皮肤粗糙度和皱纹深度方面较术前显著改善,而对照区无变化。

要点

  • 铒激光点阵消融可使烧伤增生性瘢痕的黏弹性、粗糙度和皱纹深度客观改善。
  • 治疗组与未治疗组整体比较未显示显著差异,组内自身对照可见改善。
  • 无创客观测量技术可用于评估瘢痕治疗反应。

核心结论

  • 2940nm铒激光点阵消融治疗烧伤增生性瘢痕可产生客观可测的改善,未治疗瘢痕同期无类似变化。

主要发现

  • 混合模型重复测量分析显示治疗组与对照组整体比较无显著差异。
  • 对照组瘢痕在相同时期内无组内显著变化。

临床怎么用

  • 可考虑使用2940nm铒激光点阵消融改善烧伤增生性瘢痕的黏弹性、粗糙度和皱纹深度。
  • 临床评估瘢痕疗效时可结合无创客观测量技术。

局限性

  • 样本量较小,随访至3个月时仅11例完成测量。
  • 治疗组与对照组整体比较未显示显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Their group previously demonstrated high-patient satisfaction for the treatment of hypertrophic burn scar (HBS) with the erbium: yttrium aluminum garnet (Er:YAG) laser, but this and other literature supporting the practice suffer from a common weakness of a reliance on subjective assessments by patients or providers. Herein, they sought to prospectively study the effects of Er:YAG fractional ablation on HBS using noninvasive, objective technologies to measure outcomes. Patients with HBS had identical regions of scar designated for treatment by the Er:YAG laser (TREAT) or to be left untreated (CONTROL). They prospectively collected scar measurements of TREAT and CONTROL regions preoperatively, 3 weeks, and 3 months after Er:YAG treatment. Scar measurements included viscoelastometry, transepidermal water loss, optical coherent tomography, and high-frequency ultrasound. Outcomes were measured for the aggregate difference between the TREAT group vs the CONTROL group, as well as within each group in isolation. Seventeen patients were seen preoperatively, followed by n = 15 at 3 weeks and n = 11 at 3 months. A mixed-model repeated measures analysis showed no significant effect of fractional ablation when comparing the overall TREAT group measurements with those of the CONTROL group. However, when considered as within-group measurements, TREAT scars showed significant improvement in viscoelastic deformity (P = .03), elastic deformity (P = .004), skin roughness (P = .05), and wrinkle depth (P = .04) after fractional ablation, whereas CONTROL scars showed no such within-group changes. HBS treated by the Er:YAG laser showed objective improvements, whereas no such changes were seen within the untreated scars over the same time frame.

来源:J Burn Care Res,查看原文。版权归原作者所有。

引用

  1. Madni TD, Lu K, Nakonezny PA, et al. Treating Hypertrophic Burn Scar With 2940-nm Er:YAG Laser Fractional Ablation Improves Scar Characteristics as Measured by Noninvasive Technology. J Burn Care Res. 2019. PMID: 31046088. doi:10.1093/jbcr/irz056

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。