上臂内侧皮瓣的隔皮穿支分布图谱与临床应用
回顾性分析36例患者(42侧上臂)使用上臂内侧皮瓣的重建手术,采用以内上髁为原点的坐标系统绘制隔皮穿支分布。发现至少三组穿支密集分布于内上髁至腋尖距离的88±8%、49±9%和20±6%处,所有上臂均至少有一条中或大穿支。皮瓣设计灵活,供区并发症轻微。
要点
- 穿支密集分布于臂长88%、49%、20%处,出现率分别为95.2%、100%、85.7%。
- 所有上臂至少有一条中或大穿支,90.5%有至少两条。
- 皮瓣可作远位带蒂或穿支螺旋桨皮瓣,平均面积157.9±64.5 cm²。
核心结论
- 上臂内侧皮瓣隔皮穿支分布丰富,可可靠获取,设计灵活,供区并发症轻微,值得在重建外科中更多关注。
研究设计与样本
- 回顾性研究纳入36例连续患者(42侧上臂),均接受上臂内侧皮瓣重建手术。
- 采用以内上髁为原点、y轴指向腋尖的坐标系统进行隔皮穿支定位。
主要发现
- 沿上臂内侧肌间隔识别至少三条穿支,密集位于内上髁至腋尖距离的88±8%、49±9%、20±6%处。
- 穿支出现率分别为95.2%、100%、85.7%;所有上臂至少有一条中或大穿支,90.5%有至少两条。
- 36例皮瓣术前扩张,平均面积157.9±64.5 cm²(范围40-330 cm²)。
- 除1例穿支皮瓣部分坏死需替换外,其余皮瓣全部成功,供区并发症轻微。
临床怎么用
- 可依据穿支密集点(臂长88%、49%、20%处)设计上臂内侧皮瓣,选择远位带蒂或穿支螺旋桨形式修复头颈、手、腋窝、肘部或胸壁缺损。
- 术前可考虑皮瓣扩张以获得较大面积(平均157.9 cm²),并注意保护至少一条中或大穿支。
局限性
- 回顾性设计,样本量36例(42侧上臂),未设对照组。
- 穿支定位基于特定坐标系统,结果的外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The medial arm flap has a long history but remains underused despite providing multiple advantages. We reviewed our experience with using the medial arm flap to clarify the distribution of septocutaneous perforators and its relationship with pedicled flap design. PATIENTS AND METHODS: This retrospective study included 36 consecutive patients who underwent reconstructive surgery with a medial arm flap (42 arms). Septocutaneous perforator mapping was conducted using a refined coordinate system originating at the medial epicondyle, with the y-axis running to the axillary apex. RESULTS: At least three perforators were identified along the medial intermuscular septum of the arm, located densely at 88 ± 8%, 49 ± 9%, and 20 ± 6% of the distance between the medial epicondyle and axillary apex (i.e., arm length), with a prevalence of 95.2%, 100%, and 85.7%, respectively. All arms had at least one medium- or large-sized perforator, and 90.5% of arms had at least two such perforators. Twenty-nine flaps were transferred as pedicled distant flaps for head and neck reconstruction or hand reconstruction, while the remaining 13 were transferred as perforator-based propeller flaps for axillary, elbow, or chest wall reconstruction. Thirty-six flaps underwent pre-transfer expansion. The average flap size was 157.9 ± 64.5 cm2 (range: 40-330 cm2). All flaps were successful, except for one perforator-based flap, which was replaced due to partial loss. Donor site morbidity was minimal. CONCLUSIONS: Given its rich septocutaneous perforator distribution, the medial arm flap can be harvested reliably with versatile design and minimal donor site morbidity, thus deserving more attention in reconstructive surgery.
引用
- Xue B, Zang M, Chen B, et al. Septocutaneous perforator mapping and clinical applications of the medial arm flap. J Plast Reconstr Aesthet Surg. 2019. PMID: 30808600. doi:10.1016/j.bjps.2019.01.025