智能手机增强现实显微外科规划(ARM-PS):口袋里的解剖路线图
本研究将CT血管造影三维重建的腹股沟与下腹部血管解剖图像导入智能手机,用增强现实(AR)应用叠加于摄像头画面,形成ARM-PS解剖路线图,用于SCIP皮瓣规划。在60个腹股沟区中,ARM-PS绘图与手持多普勒结果对SIEA及SCIP浅、深支的符合率为100%;30例术中所示血管与淋巴结位置与ARM-PS绘图完全一致,皮瓣切取时间较传统计时减少20%。
要点
- ARM-PS与手持多普勒在SIEA及SCIP分支定位上符合率达100%。
- 30例术中血管与淋巴结位置与ARM-PS绘图完全一致。
- 皮瓣切取时间较传统计时减少20%,可标准化皮瓣切取。
核心结论
- ARM-PS是一种简便、无创、准确的方法,提供解剖路线图,可标准化皮瓣切取,与术中所见完全一致。
- 该方法减少手术时间,可能改善手术效果并降低供区并发症。
研究设计与样本
- 前瞻性报告ARM-PS用于SCIP皮瓣规划,三维血管解剖图像来自CT血管造影并导入智能手机AR应用叠加于摄像头。
- 共研究60个腹股沟区,30例病例接受ARM-PS绘图与术中对照,并与手持多普勒结果相关。
主要发现
- ARM-PS绘图与手持多普勒结果在60个腹股沟区中对SIEA及SCIP浅、深支的符合率为100%。
- 30例术中所示血管与淋巴结位置与ARM-PS绘图完全一致。
- 皮瓣切取时间较传统计时减少20%。
关键数值与推荐
- SIEA及SCIP浅、深支定位:ARM-PS与手持多普勒符合率100%(60个腹股沟区)。
- 血管与淋巴结位置:术中与ARM-PS绘图完全一致(30例)。
- 皮瓣切取时间:较传统计时减少20%。
临床怎么用
- 术前用CT血管造影三维重建配合智能手机AR叠加,可在床旁或术前标记时形成解剖路线图,辅助SCIP皮瓣设计与切取。
- 可将ARM-PS绘图与手持多普勒互参,用于定位SIEA及SCIP分支和淋巴结,并用于标准化切取流程以缩短手术时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Perioperative microsurgical planning increases the likelihood of successful results. Augmented reality (AR) is the addition of artificial information to allow the user to perform tasks more efficiently. The aim of our study is to report the use of AR for microsurgical planning with a smartphone (ARM-PS) as a dissection route map. PATIENTS AND METHODS: AR was used for superficial circumflex iliac artery perforator (SCIP) flap planning. Three-dimensional (3D) reconstruction images of the inguinal and lower abdomen vascular anatomy were obtained by computed tomography angiography. These 3D images were imported to a smartphone and an AR app was used to superimpose them with the camera. The drawings performed with ARM-PS were correlated with handheld Doppler and intraoperative findings. RESULTS: The correlation of ARM-PS drawings with handheld Doppler results was 100% for superficial inferior epigastric artery (SIEA) and superficial and deep branches of SCIP in 60 inguinal areas studied. Intraoperative findings matched perfectly in all 30 cases with ARM-PS drawings for the location of the mentioned vessels and lymph nodes. Flap harvest time decreased in 20% compared with our traditional timing. CONCLUSIONS: ARM-PS is an easy, noninvasive, and accurate method that provides a dissection route map, thereby standardizing flap harvesting, and shows a perfect correlation with intraoperative findings. It reduces operating time and may improve operative results, thus decreasing donor site morbidity.
引用
- Pereira N, Kufeke M, Parada L, et al. Augmented Reality Microsurgical Planning with a Smartphone (ARM-PS): A dissection route map in your pocket. J Plast Reconstr Aesthet Surg. 2018. PMID: 30611677. doi:10.1016/j.bjps.2018.12.023