文献速递乳房整形与再造美容整形

自体脂肪隆胸术后脂肪坏死的处理经验

Management of Fat Necrosis after Autologous Fat Transplantation for Breast Augmentation.
PubMed 文献 · Plast Reconstr Surg · 2018-01-01

基于作者制定的处理流程进行抽吸或切除,57例有症状患者中94.7%症状显著改善。

要点

  • 自体脂肪隆胸术后脂肪坏死发生率为9.6%,首次发现肿块平均在术后108天。
  • 脂肪坏死表现为单发或多发囊肿、硬化结节或钙化,可经临床和影像学检出。
  • 按作者流程行抽吸或切除,94.7%有症状患者症状显著改善。

核心结论

  • 自体脂肪隆胸术后脂肪坏死可成功处理,94.7%患者相关症状可缓解,基于合理流程可安全处理。

研究设计与样本

  • 回顾性病例系列,5年间685名亚洲女性(20-58岁)接受自体脂肪隆胸,平均每侧注射205±45 cc,平均随访208±36天。

主要发现

  • 单侧乳房平均体积增加135±20 cc,平均脂肪留存率65%。
  • 首次发现乳房肿块的平均时间为108±45天。
  • 57例有症状患者中54例(94.7%)触痛、疼痛或可能皮肤反应显著改善。

关键数值与推荐

  • 脂肪坏死处理基于作者治疗流程,选择抽吸或切除。

临床怎么用

  • 术后应通过临床检查和影像学监测脂肪坏死,发现肿块后按流程行抽吸或切除以缓解症状。

局限性

  • 证据等级为治疗性IV级,为回顾性病例系列。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Palpable lumps as sequelae of fat necrosis after fat grafting to the breast may not only cause physical or psychological symptoms to patients but also potentially complicate breast cancer screening. In this article, the authors present their experience in management of fat necrosis following fat grafting for breast augmentation. METHODS: Over a 5-year period, a total of 685 Asian women (age range, 20 to 58 years) underwent autologous fat transplantation to the breasts. The average volume of fat graft to each breast was 205 ± 45 cc. The preoperative and postoperative photographs and the breast volume were recorded. Detection of fat necrosis was based on clinical examinations and imaging studies. The mean follow-up was 208 ± 36 days. RESULTS: The mean volume increase was 135 ± 20 cc in a single breast, with a mean graft retention rate of 65 percent. Sixty-six patients (9.6 percent) were found to have fat necrosis in the form of solitary or multiple cysts, sclerotic nodules, or calcifications in either one or both breasts postoperatively. The average time before first detection of the breast lump was 108 ± 45 days. Management of fat necrosis included aspiration or excision based on the authors' treatment algorithm. The symptoms related to fat necrosis such as discomfort on palpation, pain, or possible skin reaction were significantly improved in 54 of 57 patients (94.7 percent). CONCLUSIONS: Fat necrosis following autologous fat grafting for breast augmentation can be managed successfully and its related symptoms can be relieved in 94.7 percent of patients. It can be approached safely based on a sound algorithm developed by the authors. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Lin JY, Song P, Pu LLQ, et al. Management of Fat Necrosis after Autologous Fat Transplantation for Breast Augmentation. Plast Reconstr Surg. 2018. PMID: 30511971. doi:10.1097/PRS.0000000000004898

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。