低强度激光治疗对乳房假体包膜挛缩无效:LaTCon随机对照试验结果
结果显示两组患者报告结局及医生报告的对称性、形态、自然度均无显著差异,安慰剂组在乳房柔软度和挛缩程度改善上显著更优,结论为低强度激光无效。
要点
- 低强度激光治疗未改善患者报告的疼痛、紧绷感、手臂活动或外观。
- 安慰剂组在医生报告的乳房柔软度和挛缩程度改善上显著优于激光组。
- 证据等级为治疗性I级,不支持低强度激光用于包膜挛缩。
核心结论
- 低强度激光不是治疗乳房再造患者假体包膜挛缩的有效疗法。
研究设计与样本
- 参与者为假体再造完成至少6个月者,随机接受每周一次、共6周的活性或非活性低强度激光手柄(Riancorp LTU-904)治疗。
- 治疗完成后1个月和6个月进行评估,采用患者问卷和医生报告评估结局。
主要发现
- 两组患者报告结局(疼痛、紧绷感、手臂活动、外观)的变化均无显著差异。
- 医生报告的乳房对称性、形态、自然度变化在两组间无显著差异。
- 安慰剂组在1个月和6个月随访时医生报告的乳房柔软度(p < 0.05)和挛缩程度(p < 0.05)改善均显著优于激光组。
临床怎么用
- 临床不应将低强度激光作为乳房假体包膜挛缩的治疗选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Breast reconstruction with implants can be complicated by symptomatic capsular contracture, especially after radiotherapy. A phase I, nonrandomized clinical trial demonstrated improvement in capsular contracture and avoidance of revision surgery with low-level laser therapy. This phase II, double-blind, randomized controlled trial assessed the efficacy of low-level laser for treating capsular contracture in women with breast reconstruction following mastectomy for breast cancer. METHODS: Participants had completed their definitive implant-based reconstruction a minimum of 6 months previously and were randomized to weekly treatments over 6 weeks with either an active or inactive low-level laser handpiece (Riancorp LTU-904). Pain, tightness, arm movement, and appearance were assessed by patient questionnaires. Breast symmetry, shape, naturalness, softness, and grade of contracture were assessed by clinician reports. Participants were assessed at 1 and 6 months after completion of the treatments. RESULTS: A total of 42 patients (intervention arm, n = 20; placebo, n = 22) were assessed in the trial. Thirty-two had postmastectomy radiotherapy. There was no significant difference in the change in any patient-reported outcomes or clinician-reported outcomes of breast symmetry, shape, or naturalness for the two groups. There was a significantly greater improvement in clinician-reported breast softness (p < 0.05) and degree of contracture (p < 0.05) in the placebo group at both 1- and 6-month follow-up. CONCLUSION: Low-level laser is not an effective therapy for breast implant capsular contracture in reconstruction patients. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, I.
引用
- Azimi F, Flitcroft K, Mathieu E, et al. Low-Level Laser Treatment Is Ineffective for Capsular Contracture: Results of the LaTCon Randomized Controlled Trial. Plast Reconstr Surg. 2018. PMID: 30511966. doi:10.1097/PRS.0000000000004826
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。