文献速递乳房整形与再造

BREAST-Q计算机自适应测试:乳房再造术后简短个性化患者报告结局评估

Introducing BREAST-Q Computerized Adaptive Testing: Short and Individualized Patient-Reported Outcome Assessment following Reconstructive Breast Surgery.
PubMed 文献 · Plast Reconstr Surg · 2019-01-01

该研究开发了BREAST-Q乳房满意度量表的计算机自适应测试(CAT),通过模拟研究和5000例乳房再造患者数据验证,CAT可将问卷从16题减至平均10题(个体测量精度SE 0.32)或4题(组间研究精度SE 0.55),且与完整量表评分高度相关(模拟研究0.91-0.98,患者数据0.89-0.98)。

要点

  • CAT可将BREAST-Q乳房满意度量表题目减少38%-75%,同时保持测量可靠性。
  • 个体测量精度(SE 0.32)平均需10题,组间研究精度(SE 0.55)平均需4题。
  • CAT评分与完整量表评分高度相关,模拟研究r=0.91-0.98,患者数据r=0.89-0.98。

核心结论

  • 将计算机自适应测试应用于BREAST-Q乳房满意度量表,可在减少38%-75%题目的同时实现可靠评估。
  • 新型BREAST-Q CAT版本可能降低应答负担,有助于克服常规护理中实施的障碍。

研究设计与样本

  • 开发计算机自适应测试(CAT),从16个问题库中重复施测直至达到预设信度水平(SE 0.32-0.55)。
  • 模拟研究测试CAT对所有潜在满意度评分的可行性。
  • 第二项研究从大型数据库中随机选取5000例曾完成完整量表的乳房再造患者,比较完整量表评分与CAT衍生评分。

主要发现

  • 个体患者测量采用最低精度水平(SE 0.32)时,CAT平均需10题;组间研究采用最低精度水平(SE 0.55)时,平均需4题。
  • 模拟研究中CAT评估与完整量表评分估计高度相关(0.91-0.98)。
  • 患者数据研究中CAT评估与完整量表评分估计高度相关(0.89-0.98)。

临床怎么用

  • 在常规护理中可使用BREAST-Q CAT版本减少患者应答负担,同时保持测量可靠性。
  • 根据评估目的选择精度水平:个体测量需更高精度(SE 0.32,平均10题),组间研究可用较低精度(SE 0.55,平均4题)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The BREAST-Q is a widely used patient-reported outcome instrument measuring health-related quality-of-life and patient satisfaction in breast surgery. Shorter assessment potentially increases patients' willingness to complete scales, but simply offering a shortened version leads to unacceptable loss in measurement precision. The authors aimed to develop a computerized adaptive test (CAT) to shorten the BREAST-Q's Satisfaction with Breasts scale while maintaining reliability of measurement. METHODS: The authors created a CAT, which repetitively administered questions from the pool of 16 questions, until prespecified levels of reliability were reached [i.e., standard errors (SE) of 0.32 to 0.55]. In a simulation study, the authors tested the CAT's feasibility for all potential satisfaction scores. In a second study using actual patient data, 5000 breast reconstruction patients who had previously completed the full scale were randomly selected from a large database. Their full-scale satisfaction scores were compared with their CAT-derived scores. RESULTS: In both studies, by applying CAT, the Satisfaction with Breasts scale could be reduced to an average of 10 questions when using the minimum level of measurement precision for individual-patient measurement (SE, 0.32), compared with four questions when using the minimum precision level for group-based research (SE, 0.55). Score estimates were highly correlated between the CAT assessment and the full scale (0.91 to 0.98 in the simulation study, and 0.89 to 0.98 in the patient data study). CONCLUSIONS: Applying computerized adaptive testing to the BREAST-Q's Satisfaction with Breasts scale facilitates reliable assessment, with 38 to 75 percent fewer questions than the full version. The novel BREAST-Q CAT version may decrease response burden and help overcome barriers to implementation in routine care.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Young-Afat DA, Gibbons C, Klassen AF, et al. Introducing BREAST-Q Computerized Adaptive Testing: Short and Individualized Patient-Reported Outcome Assessment following Reconstructive Breast Surgery. Plast Reconstr Surg. 2019. PMID: 30589822. doi:10.1097/PRS.0000000000005314

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。