内侧柱岛状皮瓣用于上极缺损的肿瘤整形乳房重建
皮瓣以胸廓内动脉穿支为蒂,平均随访12个月,并发症率23.3%,再手术率16.7%,无皮瓣或乳头乳晕坏死,患者满意度高。
要点
- 内侧柱岛状皮瓣血供可靠,以第4肋间胸廓内动脉穿支为蒂。
- 该皮瓣可旋转重建上极缺损,并与上内侧蒂联合实现乳头移位。
- 并发症率23.3%、再手术率16.7%,无皮瓣或乳头乳晕坏死。
核心结论
- 内侧柱岛状皮瓣基于胸廓内动脉系统血供可靠,可安全有效重建上极肿瘤切除缺损,无重大并发症。
主要发现
- 优势胸廓内动脉穿支恒定位于第4肋间,距胸骨中线平均8.5 cm(范围8至10 cm)。
- 缺损平均大小170 cm³(范围48至295 cm³),28例(多数)患者同期行对侧乳房对称手术。
- 并发症率23.3%,再手术率16.7%,无皮瓣受损或乳头乳晕坏死证据。
- 患者满意度高,平均评分4.1分(范围2至5分,满分5分)。
临床怎么用
- 对于上极肿瘤切除后缺损,可利用下极组织设计内侧柱岛状皮瓣,以胸廓内动脉穿支为蒂,完全游离后旋转植入缺损。
- 该皮瓣可与上内侧蒂联合使用,便于乳头移位和皮瓣嵌入,实现肿瘤整形重建。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Breast deformity is common following lumpectomy. Use of ptotic lower pole tissue for restoration of volume in the upper pole is quite appealing since it allows for a concomitant lift. This study presents the medial pillar island flap technique of oncoplastic breast reconstruction of upper pole defects. METHODS: Vascular anatomy of the lower pole of the breast was investigated with cadaver study. The medial pillar island flap was designed utilizing the territory of the inferior pole of the breast as an island flap pedicled medially by the internal mammary artery perforators surrounded by the soft tissue of the medial pillar. It was transposed to the upper pole lumpectomy defect as an independent flap from superomedial pedicle which was utilized for nipple transposition. RESULTS: The dominant internal mammary artery perforator supplying the medial pillar island flap was consistently found in the fourth interspace at a mean distance of 8.5 cm (range, 8 to 10) from the sternal midline. Thirty patients underwent the procedure, with a mean age of 61 years and mean body mass index of 28.9. The average size of the defect was 170 cm(3) (range, 48 to 295 cm(3)). The majority of the patients (n = 28) underwent opposite breast symmetry surgery as well. The average follow up was 12 months. Complication rate was 23.3%. Reoperation rate was 16.7%. There was no evidence of flap compromise or nipple areola complex necrosis. Patient satisfaction was high, with a mean score of 4.1 (range, 2 to 5) out of 5. CONCLUSIONS: The medial pillar island flap has reliable vascularity based on the internal mammary artery system. The flap carries lower pole breast tissue as confined by the medial and lateral pillars of a vertical mastopexy design, offering unrestricted arc of rotation for effective reconstruction of upper pole lumpectomy defects as it is completely dissected from the chest wall and the inframammary fold. The two flap design, along with superomedial pedicle, accomplishes versatility for flap inset. The technique was proven to result in safe outcomes without major complications.
引用
- Akyurek M, Tomczyk E, Albert M, et al. The Medial Pillar Island Flap for Oncoplastic Breast Reconstruction of Upper Pole Defects. Ann Plast Surg. 2019. PMID: 30557184. doi:10.1097/SAP.0000000000001673
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。