蒂部扭转对多区域穿支皮瓣动态穿支体存活影响的实验研究
本研究在大鼠多区域穿支皮瓣模型中探究蒂部360°扭转对动态穿支体存活的影响。15只大鼠双侧背部分别制作含两个相邻动态穿支体的肋间动脉穿支皮瓣,右侧为扭转组(蒂部360°扭转),左侧为对照组。结果显示两组皮瓣灌注无显著差异,术后第7天存活率分别为98.94±1.24%和99.03±1.86%(p>0.05),血管造影显示扩张的choke血管连接三个穿支体。结论认为在精细解剖蒂部后,360°扭转未对动态穿支体灌注或存活产生不利影响。
要点
- 大鼠多区域穿支皮瓣模型中,蒂部360°扭转未显著影响皮瓣灌注与存活。
- 术后第7天扭转组与对照组存活率分别为98.94±1.24%与99.03±1.86%(p>0.05)。
- 扭转后扩张的choke血管仍连接相邻穿支体,动态穿支体存活符合穿支体理论。
核心结论
- 在精细解剖蒂部后,360°蒂部扭转未对多区域穿支皮瓣的动态穿支体灌注或存活产生不利影响。
研究设计与样本
- 实验研究,使用15只大鼠,双侧背部分别制作含两个相邻动态穿支体的肋间动脉穿支皮瓣,右侧为360°扭转组,左侧为对照组。
主要发现
- 术后第1天荧光血管造影显示两组皮瓣均有血供,激光多普勒显示术后皮瓣灌注逐日增加。
- 两组动态穿支体灌注差异无显著意义。
- 术后第7天扭转组平均存活率为98.94±1.24%,对照组为99.03±1.86%,组间差异无显著意义(p>0.05)。
- 血管造影显示两组中扩张的choke血管连接三个穿支体。
关键数值与推荐
- 扭转组与对照组术后第7天平均存活率分别为98.94±1.24%与99.03±1.86%(p>0.05)。
临床怎么用
- 提示在精细解剖蒂部的前提下,穿支皮瓣蒂部360°扭转可能不会显著影响皮瓣灌注与存活。
局限性
- 本研究为大鼠实验模型,样本量15只,结论需进一步临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Necrosis of propeller flaps is a problem in clinical practice. This study was performed to investigate the effects of pedicle torsion on dynamic perforasome survival using a multiterritory perforator flap model in rats. METHODS: Intercostal artery perforator flaps (IC flaps) containing two adjacent dynamic perforasomes were applied to both sides of the dorsum in 15 rats. The IC vessels were dissected carefully under 10 × magnification. A 360° arc of pedicle torsion was applied to the right IC flaps, which comprised the rotary group. Left IC flaps were used as controls. Flap perfusion, viability, and angiography were compared between the two groups. RESULTS: Sodium fluorescein angiography showed that there was blood supply to the flap in both groups on postoperative day (POD) 1, and laser Doppler images indicated that flap perfusion increased daily after surgery. The differences in perfusion of dynamic perforasomes between the two groups were not significant. The mean survival rate of the rotary group was not significantly different from that of the control group (98.94 ± 1.24% versus 99.03 ± 1.86%, respectively, p > 0.05) on POD 7. Angiography showed that dilated choke vessels connected the three perforasomes in both groups. CONCLUSIONS: The 360° arc of pedicle torsion had no detrimental effect on dynamic perforasome perfusion or survival in a multiterritory perforator flap model after meticulous surgical dissection of the pedicle in this study. The dilated choke vessel connected adjacent perforasomes, and the dynamic perforasome survival still adhered to the perforasome theory after pedicle torsion.
引用
- Wang L, Wu H, Lin C, et al. Effects of pedicle torsion on dynamic perforasome survival in a multiterritory perforator flap model: An experimental study. J Plast Reconstr Aesthet Surg. 2018. PMID: 30501973. doi:10.1016/j.bjps.2018.10.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。