后肋间动脉穿支皮瓣用于后躯干重建:高分辨率超声穿支定位与临床应用
该研究用高分辨率超声在10名健康志愿者中探测第4至12肋间后肋间动脉穿支(PICAP)的走行与分布,并将其用于10例后躯干缺损重建。
要点
- PICAP皮瓣可经螺旋桨或V-Y方式转移,实现后躯干「以近似组织替代」。
- 多数供区可一期闭合,供区并发症较少;本组3例出现血清肿、血肿或远端边缘坏死。
核心结论
- 研究证实后肋间动脉穿支皮瓣具有可靠的血管基础,可用于后躯干局部重建。
- 该皮瓣可经螺旋桨或V-Y方式转移,多数供区可一期闭合,供区并发症较少。
研究设计与样本
- 前瞻性穿支定位研究:用高分辨率超声在10名健康志愿者中探测第4至12肋间后肋间动脉穿支的位置、直径、筋膜上长度及走行。
主要发现
- 3例出现并发症:1例血清肿、1例血肿、1例远端边缘坏死。
临床怎么用
- 术前可用高分辨率超声定位PICAP穿支,辅助设计后躯干局部皮瓣。
- 对后躯干缺损可选择PICAP皮瓣,以螺旋桨或V-Y方式转移,多数供区可一期闭合。
局限性
- 穿支定位仅纳入10名健康志愿者,样本量有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Pedicled perforator flaps have progressively been used for reconstructive purposes of the anterior trunk. However, reports regarding perforator flaps for local reconstruction of the posterior trunk are sparse. The aim of this study was to investigate the vascular basis of perforator flaps based on the posterior intercostal arteries and to highlight the clinical versatility of these flaps for local posterior trunk reconstruction. METHODS: The posterior intercostal artery perforators (PICAP) between the 4th and 12th intercostal space were investigated using high resolution ultrasound in ten healthy volunteers. The location, diameter, suprafascial length and course of the individual perforators was measured. PICAP flaps were used in a series of ten cases for defect reconstruction of the posterior trunk to demonstrate their clinical versatility. RESULTS: A total number of 100 perforators was investigated. The mean diameter was 0,7 ± 0,24 mm with an average length until arborisation of 0,8 ± 0,8 cm. Perforators were located at 2,4 ± 1,8 cm from the midline on average. Only 16% of all measured perforators were identified as major perforators (diameter ≥ 1 mm). In ten patients (mean age at surgery 61,7 years, f:m = 3:7) a PICAP flap was used for defect reconstruction at the back with a mean follow-up of 2,9 years. Flap dimensions ranged from 7 × 3 to 16 × 7 cm. In three cases, a complication was observed (one seroma, one hematoma, one marginal tip necrosis). CONCLUSION: In the present study, a reliable vascular basis of the posterior intercostal artery perforator flap could be demonstrated. Clinically these flaps replace "like with like" and may be transposed in a propeller - or V to Y - fashion. The donor site can be closed primarily in most cases, thus resulting in a favorable donor side morbidity.
引用
- Schmidt M, Moritz T, Shamiyeh A, et al. Posterior intercostal artery perforator flap for posterior trunk reconstruction: Perforator mapping with high-resolution ultrasound and clinical application. J Plast Reconstr Aesthet Surg. 2018. PMID: 30578046. doi:10.1016/j.bjps.2018.12.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。