文献速递显微修复重建创面修复

硅胶基周围神经显微外科模拟模型

Silicone-based simulation models for peripheral nerve microsurgery.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2018-11-15

研究利用硅胶设计并制作模拟周围神经分层结构的训练模型,通过万能试验机表征力学性能并用扫描电镜评估针孔损伤。含83.3 wt%硅油与0.1 wt%棉纤维的配方被选为神经束材料,83.3 wt%硅油加棉纤维及66.6 wt%硅油无纤维在1 mm壁厚下提供类似神经外膜的显微缝合反应,模型可模拟五度神经损伤修复。

要点

  • 硅胶模型可机械与外观模拟人周围神经组织。
  • 83.3 wt%硅油加0.1 wt%棉纤维用作神经束配方。
  • 1 mm壁厚下两种硅胶配方显微缝合反应类似神经外膜。

核心结论

  • 所提出的周围神经模型在机械与外观上模拟人体组织,并实现了五度神经损伤修复的模拟。

研究设计与样本

  • 研究采用多种硅胶配方设计并制作模拟周围神经分层结构的模型。
  • 通过万能试验机表征力学性能,并用扫描电镜评估针在进入点造成的损伤。

主要发现

  • 含83.3 wt%硅油与0.1 wt%棉纤维的配方被选作神经束材料。
  • 83.3 wt%硅油加棉纤维与66.6 wt%硅油无纤维在1 mm壁厚下提供类似神经外膜的显微缝合反应。
  • 扫描电镜确认针进入未在显微缝合位点引入显著孔洞。

关键数值与推荐

  • 神经束配方为83.3 wt%硅油与0.1 wt%棉纤维。
  • 显微缝合反应评估条件为壁厚1 mm。

临床怎么用

  • 该模型可为外科受训者在尸体或动物模型练习前提供技术技能训练平台。
  • 该模型有潜力作为评估外科医生技能组合的标准化测试介质。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is a need for a peripheral nerve model on which surgeons-in-training can simulate the repair of nerve injuries at their own pace. Although practicing on animal models/cadavers is considered the "gold standard" of microsurgical training, the proposed model aims to provide a platform for improving the technical skills of surgical trainees prior to their practice on cadaver/animal models. In addition, this model has the potential to serve as a standardized test medium for assessing the skill sets of surgeons. METHODS: Several formulations of silicone were utilized for the design and fabrication of a model which realizes the hierarchical structure of peripheral nerves. The mechanical properties were characterized via the Universal Testing Machine; the damage caused by the needle on the entry sites was assessed through scanning electron microscopy (SEM). RESULTS: Mechanical properties of the formulations of silicone were tested to mimic human peripheral nerves. A formulation with 83.3 wt% silicone oil and 0.1 wt% cotton fiber was chosen to be used as nerve fascicles. Both 83.3 wt% silicone oil with cotton fiber and 66.6 wt% silicone oil without fiber provided a microsuturing response similar to that of epineurium at a wall thickness of 1 mm. SEM also confirmed that the entry of the needle did not introduce significant holes at the microsuturing sites. CONCLUSIONS: The proposed peripheral nerve model mimicked human tissues mechanically and cosmetically, and a simulation of the repair of a fifth-degree nerve injury was achieved.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Gul BU, Yanilmaz DK, Arslan D, et al. Silicone-based simulation models for peripheral nerve microsurgery. J Plast Reconstr Aesthet Surg. 2018. PMID: 30487050. doi:10.1016/j.bjps.2018.10.025

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。