文献速递烧伤创面修复

血清1,3-β-D-葡聚糖对严重烧伤患者念珠菌血症诊断的临床意义

The Clinical Significance of Serum 1,3-β-D-Glucan For the Diagnosis of Candidemia in Severe Burn Patients.
PubMed 文献 · J Burn Care Res · 2019-01-01

该回顾性研究分析了51例严重烧伤患者,这些患者因怀疑侵袭性真菌感染而检测了血清1,3-β-D-葡聚糖水平。念珠菌血症组与非念珠菌血症组的1,3-β-D-葡聚糖水平存在显著差异,最佳截断值为40 pg/ml时灵敏度100%、特异度95%,而传统截断值11 pg/ml时特异度仅68%。研究表明该检测有助于严重烧伤患者念珠菌血症的诊断,截断值可能设为40 pg/ml以更准确检测。

要点

  • 严重烧伤患者念珠菌血症组1,3-β-D-葡聚糖中位数90.6 pg/ml,非念珠菌血症组6.8 pg/ml。
  • 最佳截断值40 pg/ml灵敏度100%、特异度95%,优于传统11 pg/ml(特异度68%)。
  • 建议严重烧伤患者怀疑念珠菌血症时采用40 pg/ml作为1,3-β-D-葡聚糖截断值。

核心结论

  • 血清1,3-β-D-葡聚糖检测有助于严重烧伤患者念珠菌血症的诊断,截断值可能设为40 pg/ml以更准确检测。

研究设计与样本

  • 回顾性分析51例严重烧伤患者,这些患者因怀疑侵袭性真菌感染而检测了血清1,3-β-D-葡聚糖水平。

主要发现

  • 念珠菌血症组1,3-β-D-葡聚糖范围为41.1至600.0 pg/ml,中位数90.6 pg/ml;非念珠菌血症组范围为5.0至41.3 pg/ml,中位数6.8 pg/ml。
  • 两组1,3-β-D-葡聚糖水平存在显著差异。
  • 最佳截断值40 pg/ml时灵敏度100%、特异度95%;传统截断值11 pg/ml时灵敏度100%、特异度68%。

关键数值与推荐

  • 最佳截断值40 pg/ml,灵敏度100%,特异度95%。
  • 传统截断值11 pg/ml,灵敏度100%,特异度68%。

临床怎么用

  • 对严重烧伤患者怀疑念珠菌血症时,可检测血清1,3-β-D-葡聚糖,并考虑采用40 pg/ml作为截断值以提高诊断准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Although the serum 1,3-β-D-glucan test has been used as an early diagnostic marker of candidemia, there are few studies regarding the association of serum 1,3-β-D-glucan levels with candidemia in severe burn patients. The purpose of this study was to elucidate the clinical significance of 1,3-β-D-glucan for the diagnosis of candidemia in severe burn patients. Data from 51 severe burn patients whose serum levels of 1,3-β-D-glucan had been measured for the suspicion of invasive fungal infection were analyzed retrospectively. The primary outcome in this study was the detection of candidemia. The levels of 1,3-β-D-glucan (pg/ml) in candidemia and noncandidemia groups ranged from 41.1 to 600.0 with a median of 90.6 and from 5.0 to 41.3 with a median of 6.8, respectively. A significant difference in the levels of 1,3-β-D-glucan was observed between the two groups. The optimal cutoff value was 40 pg/ml, with a sensitivity of 100% and a specificity of 95%, whereas the conventional cutoff value (11 pg/ml) resulted in a sensitivity of 100% and a specificity of 68%. The 1,3-β-D-glucan test was found to be useful for detecting candidemia in severe burn patients, and the cutoff value might be set to 40 pg/ml to detect it more accurately.

来源:J Burn Care Res,查看原文。版权归原作者所有。

引用

  1. Kaita Y, Tarui T, Otsu A, et al. The Clinical Significance of Serum 1,3-β-D-Glucan For the Diagnosis of Candidemia in Severe Burn Patients. J Burn Care Res. 2019. PMID: 30365029. doi:10.1093/jbcr/iry055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。