乳房缩小整形术中辛基-2-氰基丙烯酸酯与黏合网对比真皮下缝合的随机对照试验
Prineo闭合速度约快6.8倍(p<0.001),每切口平均节省6.4分钟;术后2周Vancouver瘢痕量表评分Prineo组更优(p=0.026),其余时间点两组瘢痕评估无差异。结论认为Prineo瘢痕质量相似、手术成本更低且不增加并发症。
要点
- Prineo闭合平均58.38秒(2.50秒/cm),真皮下缝合444.76秒(18.94秒/cm)。
- Prineo闭合速度约快6.8倍(p<0.001),每切口平均节省6.4分钟。
- 术后2周Vancouver瘢痕量表Prineo组更优(p=0.026),其余时间点无差异。
核心结论
- 乳房缩小整形术中Prineo闭合与真皮下缝合的瘢痕质量相似且手术成本更低,不增加并发症。
- Prineo闭合速度更快,可作为真皮下缝合的有效、一致且高效的替代方案。
研究设计与样本
- 每例患者的每侧乳房随机分配至Prineo分层闭合组或真皮下缝合组。
- 术后2周、6周、6个月和1年评估切口,患者完成POSAS,两名盲法整形外科医生使用Vancouver瘢痕量表评估瘢痕质量。
主要发现
- Prineo闭合平均耗时58.38秒(2.50秒/cm),真皮下缝合平均耗时444.76秒(18.94秒/cm)。
- Prineo闭合速度约为真皮下缝合的6.8倍(p<0.001),每切口平均节省6.4分钟。
- 术后2周Vancouver瘢痕量表评分Prineo组显著更优(p=0.026)。
- 其余时间点两组POSAS和Vancouver瘢痕量表评分均无差异。
临床怎么用
- 在乳房缩小整形术中可考虑使用Prineo分层闭合以缩短手术时间并降低手术成本。
- Prineo闭合不增加并发症,术后瘢痕质量与真皮下缝合相当。
局限性
- 单中心、单盲设计,仅两名盲法评估者使用Vancouver瘢痕量表。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: An ideal wound closure system is one that is effective, consistent, and efficient. Recent studies have demonstrated the efficacy of octyl-2-cyanoacrylate and mesh (Dermabond Prineo) in the closure of surgical wounds. This study compared the use of Prineo to use of subcuticular suture closure in reduction mammaplasty. METHODS: A prospective, randomized, controlled, single-blind study of patients undergoing bilateral reduction mammaplasty was performed. Each breast per patient was randomized to layered closure with Prineo or subcuticular sutures. Incisions were assessed at 2 weeks, 6 weeks, 6 months, and 1 year. Subjects completed the Patient and Observer Scar Assessment Scale for each breast, and two blinded plastic surgeons evaluated scar quality using the Vancouver Scar Scale at each time point. RESULTS: Twenty-one patients participated in the study. On average, Prineo closure took 58.38 seconds (2.50 seconds/cm) and subcuticular closure took 444.76 seconds (18.94 seconds/cm). Prineo closure was approximately 6.8 times faster (p < 0.001) than subcuticular closure, saving an average of 6.4 minutes per incision. Vancouver Scar Scale scores were significantly better in patients with Prineo closure at 2 weeks (p = 0.026), although there was no difference in Patient and Observer Scar Assessment Scale and Vancouver Scar Scale scores at all other time points. CONCLUSIONS: In reduction mammaplasty, Prineo closure results in similar scar quality and lower operative cost without increased complications when compared to subcuticular closure. Prineo is faster than subcuticular closure and represents an effective, consistent, and efficient alternative to subcuticular suture techniques. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, II.
引用
- Lee JC, Ishtihar S, Means JJ, et al. In Search of an Ideal Closure Method: A Randomized, Controlled Trial of Octyl-2-Cyanoacrylate and Adhesive Mesh versus Subcuticular Suture in Reduction Mammaplasty. Plast Reconstr Surg. 2018. PMID: 29979362. doi:10.1097/PRS.0000000000004726
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。