计算机设计/制造异质植入物精修正颌术后面部轮廓
对Le Fort I型上颌截骨和/或双侧下颌升支矢状劈开截骨术后外观不满意者,基于CT三维重建数据用计算机辅助设计/制造定制异质植入物,经口内和颏下切口置入并以钛钉固定,21例中1例因感染取出植入物,其余满意,7年间显示可有效精修外观且并发症少。
要点
- 基于CT三维重建数据用计算机辅助设计/制造定制异质植入物。
- 经口内和颏下切口置入,钛钉固定。
- 21例中1例因感染取出植入物,其余均满意。
核心结论
- 计算机辅助设计/制造植入物的使用与手术置入在7年间21例中显示可有效精修外观且并发症少。
研究设计与样本
- 对Le Fort I型上颌前徙和/或双侧下颌升支矢状劈开截骨术后外观不满意的患者,从计算机断层扫描重建三维图像,用其数据制作计算机辅助设计/制造异质植入物并经口内和颏下切口置入、钛钉固定。
主要发现
- 共21例患者接受计算机设计/制造植入物置入,1例因感染需取出植入物,其余患者均对结果满意。
局限性
- 证据等级为治疗性IV级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Le Fort I maxillary osteotomies and sagittal split mandibular osteotomies are performed to correct significant dentofacial deformities. The multidimensional skeletal movements, particularly those of large magnitude, may result in contour irregularities and facial imbalances. METHODS: Three-dimensional images were reconstructed from computed tomographic scans in patients unhappy with their appearances after Le Fort I advancement and/or bilateral sagittal split osteotomies. The data from these scans were used to produce alloplastic implants using computer-aided design/computer-aided manufacturing for surgical correction of contour irregularities and imbalances. These implants were surgically placed through intraoral and submental incisions and fixed using titanium screws. RESULTS: A total of 21 patients underwent implant placement with implants produced using computer-design/computer manufacturing. One patient required removal of implants secondary to infection. All other patients were satisfied with their result. CONCLUSION: The use and surgical placement of implants produced by means of computer-aided design/computer-aided manufacturing has been shown to be effective in refining appearance in 21 patients over a 7-year period with minimal morbidity. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
引用
- Lee JH, Kaban LB, Yaremchuk MJ, et al. Refining Post-Orthognathic Surgery Facial Contour with Computer-Designed/Computer-Manufactured Alloplastic Implants. Plast Reconstr Surg. 2018. PMID: 29927839. doi:10.1097/PRS.0000000000004652
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。