文献速递烧伤显微修复重建创面修复

四肢电烧伤早期应用显微外科皮瓣:两机构病例系列

Early Application of Microsurgical Flaps in the Electric Burns of Extremities: A Two Institutional Case Series.
PubMed 文献 · J Burn Care Res · 2018-01-01

该回顾性病例系列评估四肢电烧伤早期显微外科皮瓣重建,5例皮瓣均在伤后30天内完成,平均伤后24.2天手术,皮瓣均存活,避免截肢并保留功能;作者认为早期应用可能提供 adequate、牢固且稳定的皮肤覆盖。

要点

  • 5例四肢电烧伤患者接受早期显微外科皮瓣,平均伤后24.2天手术。
  • 皮瓣类型为1例股前外侧皮瓣覆盖上肢皮肤缺损、4例桡前臂皮瓣覆盖足部缺损。
  • 仅1例需再次手术重新吻合血管,所有皮瓣存活,避免截肢并保留功能。

核心结论

  • 作者认为,四肢电烧伤患者早期应用显微外科皮瓣可能提供 adequate、牢固且稳定的皮肤覆盖,有助于治疗外露的重要结构并避免截肢。

研究设计与样本

  • 回顾性病例系列,纳入四肢电烧伤后接受早期显微外科重建的患者,数据来自病历。

主要发现

  • 共完成5例显微外科皮瓣,均在伤后不到30天内进行。
  • 患者年龄均值25.8岁(范围12至42岁)。
  • 显微外科手术在烧伤后21至27天进行,均值24.2天。
  • 皮瓣术后住院出院时间均值26.6天(术后19至35天)。
  • 仅1例患者需再次干预行重新吻合;所有患者皮瓣存活良好,避免截肢并适当保留功能。

关键数值与推荐

  • 1例股前外侧皮瓣覆盖上肢皮肤缺损。
  • 4例桡前臂皮瓣覆盖足部缺损。

临床怎么用

  • 作者认为,四肢电烧伤患者早期应用显微外科皮瓣可能提供 adequate、牢固且稳定的皮肤覆盖,有助于治疗外露的重要结构并避免截肢。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Some groups have avoided early microsurgical flaps in electrical burns under the pretext of injury to the microvasculature, which could increase vascular thrombosis. However, this option frequently results in amputation of the extremity. This study aims to evaluate the early application of microsurgical flaps for the treatment of electrical burns of extremities. A case series was retrospectively evaluated including patients with electrical trauma in extremities undergoing early microsurgical reconstruction. Data were obtained from medical charts, including age, trauma location, flap type and microvascular anastomosis, the need for other procedures, postoperative complications, the length of hospital stay after the flap surgery, and patient outcomes. Five microsurgical flaps were performed in less than 30 days to trauma, one anterolateral thigh flap to cover skin failure in upper limb, and four radial forearm flaps to cover failure in feet. The patient ages had a mean of 25.8 years (from 12 to 42 years). The microsurgical procedure occurred from 21 to 27 days after the burn, with a mean of 24.2 days. Hospital discharge had a mean of 26.6 days (from 19 to 35 days after the surgery). Only one patient required reintervention for re-anastomosis. All patients had a good flap viability, avoiding amputation of the affected extremity and with a proper preservation of function. The early application of microsurgical flaps for patients with electrical burns of extremities may provide adequate, sturdy, and stable skin coverage, contributing to the treatment of noble structures exposed and avoiding amputation of the extremities.

来源:J Burn Care Res,查看原文。版权归原作者所有。

引用

  1. Castro JC, Coltro PS, Millan LS, et al. Early Application of Microsurgical Flaps in the Electric Burns of Extremities: A Two Institutional Case Series. J Burn Care Res. 2018. PMID: 29931152. doi:10.1093/jbcr/irx010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。