超声弹性成像可可靠识别烧伤软组织力学特性的改变
本研究基于超声弹性成像技术,对离体猪皮肤组织施加四种烧伤条件,通过机器人控制的超声探头和力传感器压缩组织,计算二阶多项式超弹性材料模型的参数C10和C20。结果显示线性参数C10在各测试条件间无统计学显著差异,而非线性参数C20在四种烧伤条件中的三种(ii-iv)可可靠区分烧伤与未烧伤组织(p<0.05),分类准确率为60-87%。
要点
- 非线性参数C20在四种烧伤条件中的三种(ii-iv)可区分烧伤与未烧伤组织(p<0.05)。
- 线性参数C10在烧伤与未烧伤组织间无统计学显著差异。
- 非线性参数C20的分类准确率为60-87%。
核心结论
- 基于超声弹性成像的技术可可靠评估烧伤组织改变的非线性力学特性,并具有应用于在体条件下的潜力,留待未来工作。
研究设计与样本
- 离体猪皮肤组织暴露于四种烧伤条件:200°F持续10秒、200°F持续30秒、450°F持续10秒、450°F持续30秒。
- 使用包含机器人控制的超声探头和力传感器的定制仪器压缩组织样本,计算二阶多项式超弹性材料模型的C10和C20两个参数。
主要发现
- 线性模型参数C10在测试条件之间未显示统计学显著差异。
- 非线性模型参数C20在比较烧伤与未烧伤组织时,可靠识别四种情况中的三种(ii-iv)(p<0.05),分类准确率为60-87%。
- 由于胶原纤维结构的变化,观察到组织软化。
局限性
- 该技术在体条件下的应用潜力留待未来工作。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Although burn injury to the skin and subcutaneous tissues is common in both civilian and military scenarios, a significant knowledge gap exists in quantifying changes in tissue properties as a result of burns. In this study, we present a noninvasive technique based on ultrasound elastography which can reliably assess altered nonlinear mechanical properties of a burned tissue. In particular, ex vivo porcine skin tissues have been exposed to four different burn conditions: (i) 200°F for 10s, (ii) 200°F for 30s, (iii) 450°F for 10s, and (iv) 450°F for 30s. A custom-developed instrument including a robotically controlled ultrasound probe and force sensors has been used to compress the tissue samples to compute two parameters (C10 and C20) of a reduced second-order polynomial hyperelastic material model. The results indicate that while the linear model parameter (C10) does not show a statistically significant difference between the test conditions, the nonlinear model parameter (C20) reliably identifies three (ii-iv) of the four cases (p<0.05) when comparing burned with unburned tissues with a classification accuracy of 60-87%. Additionally, softening of the tissue is observed because of the change in structure of the collagen fibers. The ultrasound elastography-based technique has potential for application under in vivo conditions, which is left for future work.
引用
- Ye H, Rahul, Dargar S, et al. Ultrasound elastography reliably identifies altered mechanical properties of burned soft tissues. Burns. 2018. PMID: 29859811. doi:10.1016/j.burns.2018.04.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。