文献速递乳房整形与再造显微修复重建

自体与假体联合乳房再造:肥胖患者安全扩张上限的界定

Combined Autologous and Prosthetic Breast Reconstruction: Defining the Upper Limits of Safe Expansion in Obesity.
PubMed 文献 · Ann Plast Surg · 2018-01-01

该尸体研究由2名盲法观察者在1至6厘米厚度组织下定位Mentor CPX-4扩张器注射座,每厚度尝试30次;1至4厘米成功率100%,5厘米降至86.6%,6厘米降至43.3%。作者结论认为,皮肤捏厚度大于8厘米或皮瓣厚度大于4厘米的肥胖患者,术后扩张时应采取措施降低意外穿刺风险。

要点

  • 组织厚度1至4厘米时注射座定位成功率为100%(k=1)。
  • 组织厚度5厘米时成功率降至86.6%(k=1),6厘米时降至43.3%(k=0.85)。
  • 皮肤捏厚度大于8厘米或皮瓣厚度大于4厘米时,作者建议采取措施降低扩张期意外穿刺风险。

核心结论

  • 作者结论认为,皮肤捏厚度大于8厘米或皮瓣厚度大于4厘米的肥胖患者,术后扩张时应采取措施降低扩张器意外穿刺风险。

研究设计与样本

  • 尸体研究,由2名盲法观察者在厚度为1、2、3、4、5、6厘米的组织下尝试定位Mentor CPX-4扩张器注射座,每种厚度尝试30次。

主要发现

  • 组织厚度1至4厘米时定位成功率为100%(k=1)。
  • 组织厚度5厘米时成功率降至86.6%(k=1)。
  • 组织厚度6厘米时成功率降至43.3%(k=0.85)。
  • 点二列相关显示组织厚度大于4厘米时厚度与准确性呈负相关(r=-0.55,P<0.00001)。
  • 以4厘米为界将组织厚度转为二分类变量后,Fisher精确检验显示两组间差异有统计学意义(P<0.00001)。

关键数值与推荐

  • 皮肤捏厚度大于8厘米或皮瓣厚度大于4厘米的肥胖患者,作者建议采取措施降低术后扩张时意外穿刺风险。
  • 作者提出的措施包括:放弃组织扩张器而选用假体、超声引导下定位注射座、或使用远程注射座扩张器。

临床怎么用

  • 作者建议,皮肤捏厚度大于8厘米或皮瓣厚度大于4厘米的肥胖患者,术后扩张时应采取措施降低意外穿刺风险,包括放弃组织扩张器而选用假体、超声引导下定位注射座、或使用远程注射座扩张器。
  • 作者指出这些发现不仅适用于背阔肌皮瓣联合假体的乳房再造,也适用于任何自体与假体联合再造的情形。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Combined latissimus dorsi and prosthetic reconstruction is a useful reconstructive option in patients with a history of breast radiation who are not good candidates for abdominally based autologous reconstruction. One difficulty, particularly in obese patients, is that the thickness of the flap can impair port localization, increasing the risk of inadvertent puncture during expansion. The authors sought to investigate the upper limits of tissue thickness at which tissue expansion can be reliably performed. METHODS: A cadaveric study was designed in which 2 blinded observers attempted to localize the port of a Mentor CPX-4 expander under tissue 1, 2, 3, 4, 5, and 6 cm thick. Thirty attempts were made per tissue thickness. RESULTS: For tissue thicknesses of 1 to 4 cm, the success rate was 100% (k = 1). At 5 cm, the success rate decreased to 86.6% (k = 1); at 6 cm, 43.3% (k = 0.85). Point biserial correlation revealed a negative correlation between tissue thickness and accuracy at a thicknesses of greater than 4 cm (r = -0.55, P < 0.00001). Converting tissue thickness to a dichotomous variable based on the results (thickness, <4 and >4 cm), Fisher exact test revealed a statistically significant difference between these 2 populations (P < 0.00001). CONCLUSIONS: In obese patients with a skin pinch of greater than 8 cm or a flap thickness of greater than 4 cm, steps should be taken to minimize the risk of inadvertent puncture of the expander during postoperative expansion. This can include foregoing tissue expander placement in favor of an implant, port localization with ultrasound guidance, or the use of remote port expanders. These findings are relevant not only in breast reconstruction with latissimus flaps and implants but also in any setting where autologous and prosthetic reconstructions are combined.

来源:Ann Plast Surg,查看原文。版权归原作者所有。