文献速递乳房整形与再造显微修复重建

术前应用非罗莫司醇增强磁共振血管成像分析腹壁下动脉穿支游离皮瓣乳房再造的静脉解剖

Preoperative Analysis of Venous Anatomy Before Deep Inferior Epigastric Perforator Free-Flap Breast Reconstruction Using Ferumoxytol-enhanced Magnetic Resonance Angiography.
PubMed 文献 · Ann Plast Surg · 2023-01-01

该回顾性研究纳入2012至2016年59例术前行非罗莫司醇增强磁共振血管成像(FE-MRA)的腹壁下动脉穿支(DIEP)皮瓣乳房再造患者,共分析118个半腹壁和99个皮瓣。117个半腹壁存在浅深静脉交通,59例中50例(93%)浅静脉系统跨中线交通直径大于1mm。SIEV直径(P=0.01)、优势穿支直径(P=0.04)及两者比值(P=0.001)与SIEV增强相关。

要点

  • FE-MRA可清晰显示腹壁静脉系统解剖。
  • 117/118个半腹壁存在浅深静脉交通。
  • SIEV直径、优势穿支直径及两者比值与SIEV增强相关。

核心结论

  • 非罗莫司醇增强磁共振血管成像可提供优良的静脉系统成像。
  • SIEV直径和优势穿支直径等解剖特征可能有助于判断哪些皮瓣需要采用SIEV进行静脉增强。

研究设计与样本

  • 回顾性分析所有术前接受FE-MRA并行DIEP皮瓣乳房再造的患者。
  • 在回顾手术发现之前,对每个腹壁的FE-MRA进行详细解剖分析。
  • 采用统计学分析确定与SIEV增强相关的静脉特征。

主要发现

  • 2012年至2016年,59例患者术前行FE-MRA,共获得118个半腹壁和99个皮瓣的影像。
  • 117/118个半腹壁发现浅深静脉交通。
  • 59例患者中50例(93%)的浅静脉系统跨中线交通直径大于1mm。
  • 99个皮瓣中82个(83%)以优势内侧排穿支为血管蒂。
  • SIEV和优势静脉穿支的平均直径分别为3.8mm和2.8mm。

关键数值与推荐

  • 与SIEV增强相关的解剖特征包括SIEV直径(P=0.01)、优势穿支直径(P=0.04)及两者比值(P=0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Venous congestion after deep inferior epigastric artery perforator (DIEP) flap breast reconstruction is a complication that may be partially attributable to variations in venous abdominal wall anatomy. In previous work, we have shown that ferumoxytol may be used as a bloodpool contrast agent to perform high-resolution venous imaging. Our current aim was to use this technology to perform a detailed analysis of the venous anatomy among patients undergoing DIEP flap breast reconstruction. METHODS: All patients undergoing DIEP flap reconstruction with preoperative ferumoxytol-enhanced magnetic resonance angiography (FE-MRA) were retrospectively reviewed. A detailed anatomic analysis of each abdominal wall on FE-MRAwas performed before review of operative findings. Statistical analysis was used to determine venous characteristics associated with superficial inferior epigastric vein (SIEV) augmentation. RESULTS: From 2012 to 2016, 59 patients underwent preoperative FE-MRA. This resulted in imaging for 118 hemiabdomen and 99 flaps. Superficial-deep communication was identified in 117 of 118 hemiabdomen. Fifty (93%) of 59 patients had greater than 1-mm venous communication of the superficial system across midline. Reconstructed breasts were based on dominant medial row perforators in 82 (83%) of 99 flaps. The mean diameters of the SIEVand dominant venous perforator were 3.8 and 2.8mm, respectively. Anatomic characteristics associated with SIEVaugmentation included SIEVdiameter ( P = 0.01), dominant perforator diameter ( P = 0.04), and the ratio between these 2 variables ( P = 0.001). CONCLUSIONS: Ferumoxytol-enhanced magnetic resonance angiography provides excellent imaging of the venous system. Anatomic characteristics such as the diameter of the SIEVand the diameter of the dominant perforator may be useful in determining which flaps require venous augmentation using the SIEV.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Dortch J, Forte AJ, Bolan C, et al. Preoperative Analysis of Venous Anatomy Before Deep Inferior Epigastric Perforator Free-Flap Breast Reconstruction Using Ferumoxytol-enhanced Magnetic Resonance Angiography. Ann Plast Surg. 2023. PMID: 29762436. doi:10.1097/SAP.0000000000001421

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。