文献速递烧伤创面修复

比较光谱皮肤分析(SIA)与激光多普勒成像(LDI)在成人及儿童烧伤评估中的准确性

A comparative evaluation of spectrophotometric intracutaneous analysis and laser doppler imaging in the assessment of adult and paediatric burn injuries.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2018-03-29

研究纳入29例伤后2至5天就诊的中厚皮烧伤患者,共45个感兴趣区,分别用SIA与LDI成像并由两名临床医生独立回顾性预测愈合潜力。McNemar检验示两种方法准确性无显著差异(p=0.61),提示SIA准确性可与LDI相比,作者认为SIA有潜力作为经济、易用的辅助决策工具。

要点

  • 29例中厚皮烧伤患者、45个感兴趣区,伤后2至5天行SIA与LDI成像。
  • 两名临床医生独立回顾性预测愈合潜力,McNemar检验p=0.61。
  • 两种方法准确性无显著差异,SIA准确性可与LDI相比。

核心结论

  • 结果提示SIA的准确性可与LDI相比,作者经验认为SIA有潜力作为经济、易用的辅助决策工具。

研究设计与样本

  • 研究招募29例伤后2至5天就诊的中厚皮烧伤患者,识别45个烧伤感兴趣区,患者均接受SIA与LDI两种成像。
  • 两名临床医生根据两种方法各自的图像独立回顾性预测每个烧伤区域的愈合潜力,后续随访临床结局。

主要发现

  • McNemar检验示两种方法准确性无显著差异(p=0.61)。
  • 随访显示参与研究未影响治疗。

关键数值与推荐

  • McNemar检验:SIA与LDI准确性比较p=0.61。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Clinical assessment of mid-dermal burns can be challenging. Currently, laser Doppler imaging (LDI) is the gold standard adjunct in the assessment of burn injuries. Although LDI has demonstrated reliable accuracy, it poses various limitations in routine use including cost and ease of use. In comparison, spectrophotometric intracutaneous analysis (SIA) is a relatively cheaper technique, which can be carried out using a modified digital camera that enables easy image acquisition. We aim to compare the accuracy of the two modalities in the assessment of mid-dermal burn injuries. METHODS: We recruited 29 patients with mid-dermal burns presenting within 2 to 5 days post burn. Forty-five burn regions of interest were identified, and the patients underwent imaging using both the modalities. Subsequent clinical outcome was followed up and showed that treatment remained unaffected by participation. Two clinicians then independently predicted the healing potential of each burn region retrospectively as per images from either modality. RESULTS: McNemar's test indicated that there is no significant difference between the accuracy of the two modalities (p = 0.61). CONCLUSION: The results suggest that the accuracy of SIA is comparable to that of LDI. Our experience with SIA indicates its potential as a cost-effective and user-friendly adjunct in decision-making.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Charuvila S, Singh M, Collins D, et al. A comparative evaluation of spectrophotometric intracutaneous analysis and laser doppler imaging in the assessment of adult and paediatric burn injuries. J Plast Reconstr Aesthet Surg. 2018. PMID: 29776847. doi:10.1016/j.bjps.2018.03.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。