电烧伤与迟发性自发性动脉破裂:三例病例报告
本文报告三例因电烧伤后迟发性动脉破裂导致失血性休克的患者,部分破裂发生于受伤数月后;急诊止血以肢体近端放置止血带和/或压迫点为首选方法。作者认为,对电烧伤患者应密切监测数周,尤其合并骨筋膜室综合征和严重横纹肌溶解者,后者在本组病例中似乎是迟发性动脉破裂的预测因素。
要点
- 电烧伤可致动脉、静脉血栓形成及动脉壁削弱,引发即时或迟发性闭塞或动脉瘤。
- 迟发性动脉破裂可无预警信号,导致失血性休克,发生时间可变且不可预测。
- 急诊止血首选肢体近端止血带和/或压迫点,作者认为对电烧伤患者应密切监测数周。
核心结论
- 作者认为,对电烧伤患者应密切监测数周,尤其合并一个或多个肢体骨筋膜室综合征及严重横纹肌溶解者,后者在本组病例中似乎是迟发性动脉破裂的预测因素。
研究设计与样本
- 本文为三例电烧伤病例报告,患者在该科室接受治疗,并发症以迟发性动脉破裂继发失血性休克为特征。
主要发现
- 三例电烧伤患者的并发症均表现为迟发性动脉破裂继发的失血性休克,部分破裂发生于事件后数月。
- 迟发性动脉破裂可无任何预警信号,失血性休克的发生时间可变且不可预测。
关键数值与推荐
- 急诊止血以肢体近端放置止血带和/或压迫点为首选方法,用于控制突发出血。
临床怎么用
- 作者认为,对电烧伤患者应密切监测数周,尤其合并一个或多个肢体骨筋膜室综合征及严重横纹肌溶解者。
- 急诊止血时,首选在肢体近端放置止血带和/或使用压迫点。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Electrical burns are responsible for arterial and venous thrombosis, as well as weakening of the arteries. Immediate or delayed arterial occlusions, secondary to the aggression of the intima, or aneurysms, secondary to the aggression of the media, sometimes lead to artery ruptures without any warning signs. Such ruptures may trigger a hemorrhagic shock whose period of onset is variable and unpredictable. We are presenting here three cases treated in our department for electrical burns, whose complications were marked by hemorrhagic shock, secondary to late artery ruptures, sometimes occurring several months following the event. These case reports required performance of emergency hemostasis in order to control sudden bleeding, with first approach being placement of a tourniquet at the base of the limb and/or a compression point. Through these cases, we thought it is crucial to closely monitor for a few weeks all patients who were victims of electrical injury, even more so if it was associated with a compartment syndrome of one or more limbs and high rhabdomyolysis, which seem to be predictive factors of late artery ruptures in our case reports.
引用
- Reinbold C, Serror K, Mimoun M, et al. Electrical Burns and Late Spontaneous Artery Ruptures: About Three Cases. J Burn Care Res. 2019. PMID: 29767734. doi:10.1093/jbcr/irx005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。