无菌冻干与无菌湿包装人尸体脱细胞真皮基质在即刻组织扩张器乳房重建中的比较:倾向性评分分析
该回顾性研究纳入2006至2016年间988例即刻组织扩张器乳房重建,比较冻干与即用型人尸体脱细胞真皮基质的并发症。倾向性评分匹配384对后,冻干组手术部位并发症(21.4% vs 16.7%,p=0.10)和手术部位感染(9.6% vs 7.8%,p=0.13)略高但无显著差异,而重建失败显著更高(7.8% vs 4.4%,p=0.050)。作者结论认为脱细胞真皮基质制备方式对结局有独立影响。
要点
- 冻干组重建失败率显著高于即用型组(7.8% vs 4.4%,p=0.050)。
- 手术部位并发症和感染率冻干组略高,但差异无统计学意义。
- 作者结论认为脱细胞真皮基质制备方式对患者结局有独立影响。
核心结论
- 作者结论认为脱细胞真皮基质制备方式在其对同一公司产品的比较中对患者结局有独立影响。
- 冻干基质较即用型基质早期并发症更高,仅重建失败达到统计学显著。
研究设计与样本
- 回顾性分析了2006年至2016年间所有使用冻干或即用型人脱细胞真皮基质的异体乳房重建。
- 共纳入988例重建(冻干组53.8%,即用型组46.2%),并进行倾向性评分匹配前后比较。
主要发现
- 384对倾向性评分匹配后,冻干组手术部位并发症发生率为21.4%,即用型组为16.7%(p=0.10),差异无统计学意义。
- 冻干组手术部位感染率为9.6%,即用型组为7.8%(p=0.13),差异无统计学意义。
- 冻干组重建失败率为7.8%,即用型组为4.4%(p=0.050),冻干组显著更高。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Although multiple acellular dermal matrix sources exist, it is unclear how its processing impacts complication rates. The authors compared complications between two preparations of human cadaveric acellular dermal matrix (freeze dried and ready-to-use) in immediate tissue expander breast reconstruction to analyze the effect of processing on complications. METHODS: The authors retrospectively reviewed all alloplastic breast reconstructions with freeze-dried or ready-to-use human acellular dermal matrices between 2006 and 2016. The primary outcome measure was surgical-site occurrence defined as seroma, skin dehiscence, surgical-site infection, or reconstruction failure. The two groups were compared before and after propensity score matching. RESULTS: The authors included 988 reconstructions (freeze-dried, 53.8 percent; ready-to-use, 46.2 percent). Analysis of 384 propensity score-matched pairs demonstrated a slightly higher rate of surgical-site occurrence (21.4 percent versus 16.7 percent; p = 0.10) and surgical-site infection (9.6 percent versus 7.8 percent; p = 0.13) in the freeze-dried group than in the ready-to-use group, but the difference was not significant. However, failure was significantly higher for the freeze-dried versus ready-to-use group (7.8 percent versus 4.4 percent; p = 0.050). CONCLUSIONS: This is the largest study comparing the outcomes of alloplastic breast reconstruction using human acellular dermal matrix materials prepared by different methods. The authors demonstrated higher early complications with aseptic, freeze-dried matrix than with sterile ready-to-use matrix; reconstructive failure was the only outcome to achieve statistical significance. The authors conclude that acellular dermal matrix preparation has an independent impact on patient outcomes in their comparison of one company's product. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.
引用
- Hanson SE, Meaike JD, Selber JC, et al. Aseptic Freeze-Dried versus Sterile Wet-Packaged Human Cadaveric Acellular Dermal Matrix in Immediate Tissue Expander Breast Reconstruction: A Propensity Score Analysis. Plast Reconstr Surg. 2018. PMID: 29659450. doi:10.1097/PRS.0000000000004323
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。