文献速递显微修复重建创面修复

应用计算机断层扫描血管造影描述股外侧肌筋膜张肌穿支皮瓣的血管解剖

A Description of the Vascular Anatomy of the Tensor Fascia Lata Perforator Flap Using Computed Tomography Angiography.
PubMed 文献 · Ann Plast Surg · 2018-01-01

本研究回顾性分析33例患者(59侧大腿)术前双下肢CTA影像,描述股外侧肌筋膜张肌(TFL)穿支的数量、大小、类型、位置及血管蒂起源与长度,并与股前外侧皮瓣标志点进行关联,以辅助皮瓣规划。

要点

  • 每侧TFL平均有2.5个穿支,均起自旋股外侧动脉升支,平均血管蒂长8.3 cm(范围6.0-11.2 cm)。
  • 66%穿支为皮间隔穿支,34%为肌皮穿支;CTA测得平均穿支大小为3 mm。
  • 穿支平均位于髂前上棘至髌骨上外侧连线下方10.1 cm、外侧8.5 cm处。

核心结论

  • 据作者所知,这是首项使用高分辨率CTA描述TFL穿支皮瓣血管解剖并与大腿皮瓣规划常用标志点关联的研究。
  • 作者认为这些数据有助于皮瓣设计和分离,可能缩短手术室时间、减少用于确认大腿穿支存在的探查切口并改善患者总体结局。

研究设计与样本

  • 回顾性分析33例既往因游离皮瓣重建术前规划而行双下肢CTA的患者影像,共纳入33例患者、59侧大腿。
  • 记录TFL穿支数量、大小、类型、位置及血管蒂起源和总长度。

主要发现

  • 每侧TFL平均有2.5个穿支。
  • 所有穿支均起自旋股外侧动脉升支,平均血管蒂长度8.3 cm(范围6.0-11.2 cm)。
  • 66%的穿支为皮间隔穿支,34%为肌皮穿支。
  • CTA测得的平均穿支大小为3 mm。
  • 穿支平均位于髂前上棘至髌骨上外侧连线下方10.1 cm、外侧8.5 cm处。

临床怎么用

  • 作者认为所描述的数据有助于TFL穿支皮瓣的设计和分离,并可能与大腿皮瓣规划中常用标志点关联使用。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The perforator anatomy of the tensor fascia lata (TFL) flap has been studied using cadaver dissection; however, exact descriptions of location, size, and origin of perforator vessels using preoperative imaging modalities remain limited. The aims of this study are to describe TFL perforator anatomy using high-resolution computed tomography angiography (CTA) and to correlate these findings with landmarks for the anterolateral thigh flap to facilitate flap planning. METHODS: We identified 33 patients who previously underwent bilateral lower extremity CTAs for preoperative planning of free-flap reconstruction. The images were retrospectively reviewed, and the TFL perforator number, size, type, location, and overall pedicle origin and length were recorded. RESULTS: Thirty-three patients and 59 thighs were included in the study. There was an average of 2.5 perforators per TFL. All perforators arose from the ascending branch of the lateral circumflex femoral artery with an average pedicle length of 8.3 cm (range, 6.0-11.2 cm). Sixty-six percent of perforators were septocutaneous and 34% were musculocutaneous. The average perforator size as measured on CTA was 3 mm. The average perforator location was 10.1 cm inferior and 8.5 cm lateral to the line drawn from the anterior superior iliac spine to the superolateral patella. CONCLUSIONS: To our knowledge, this is the first study to characterize the vascular anatomy of the TFL perforator flap using high-resolution CTA and correlate this with well-established landmarks used in the planning for other thigh-based flaps. We believe data will facilitate flap design and dissection; potentially shortening operating room times, limiting exploratory incisions used to confirm the presence of thigh based perforators, and improving overall outcomes for patients.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Powers JM, Martinez M, Zhang S, et al. A Description of the Vascular Anatomy of the Tensor Fascia Lata Perforator Flap Using Computed Tomography Angiography. Ann Plast Surg. 2018. PMID: 29668509. doi:10.1097/SAP.0000000000001424

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。