超声与整形外科:最新技术的临床应用
单术者用便携式彩色多普勒超声(CDUS)对56例拟行重建或美容手术患者行术前和/或术中评估;皮瓣穿支定位与术中符合率100%,2/11例(18.2%)发现CT血管造影未检出的穿支,并用于腹壁层次显像辅助腹横肌平面阻滞及评估浅筋膜系统(SFS)。
要点
- 便携式CDUS可术前定位皮瓣最大穿支,11例术中验证符合率100%。
- 11例中2例(18.2%)CDUS发现CT血管造影未检出的穿支。
- 25例腹壁手术中术中显像腹壁肌层,辅助术者完成腹横肌平面阻滞。
核心结论
- 最新小型化CDUS技术用途多样,可能改善整形外科患者的结局与体验;作者的观察结果需进一步研究以量化该新技术的获益。
研究设计与样本
- 单术者用Philips Lumify CDUS设备线性12-4探头,对56例拟行重建或美容手术患者行术前和/或术中评估。
主要发现
- 皮瓣重建11例术前CDUS定位最大穿支,涉及腹壁下动脉穿支皮瓣、股前外侧皮瓣、阔筋膜张肌皮瓣、胸背动脉穿支皮瓣、臀上动脉穿支皮瓣及股薄肌肌皮瓣,术中验证符合率100%。
- 11例中2例(18.2%)CDUS发现CT血管造影未检出的穿支。
- 25例腹壁成形术或腹壁下动脉穿支皮瓣重建患者术中成功显像腹壁肌层,由术者完成腹横肌平面阻滞。
- 20例体形雕塑手术患者术前显像SFS,SFS在不同患者之间及同一患者内部均存在差异。
临床怎么用
- 作者认为最新小型化CDUS技术有多种应用,可能改善整形外科患者结局与体验;作者的观察结果需进一步研究以量化其获益。
局限性
- 作者指出其观察结果需进一步研究以量化该新技术的获益。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Color Doppler ultrasound (CDUS) has not been routinely used in plastic and reconstructive surgery. Barriers to use have included large, cumbersome equipment, low-definition images, cost, and availability. In addition, programs in plastic surgery have not included training with ultrasound (US); thus, many current-day practitioners are unfamiliar with and reluctant to use this technology. Nevertheless, recent studies have demonstrated the utility of US in surgical planning. With the miniaturization, clearer imaging, and decreased costs of the latest US technology, previous barriers to use have largely been eliminated. METHODS: Fifty-six patients scheduled for either reconstructive or aesthetic surgery were evaluated preoperatively and/or intraoperatively by a single surgeon with the linear 12-4 probe of a Philips Lumify CDUS device (Philips, Reedsville, Penn). For patients undergoing flap reconstruction, potential donor sites were imaged in order to locate the largest perforator. For patients undergoing abdominal procedures, intraoperative visualization of the abdominal muscular layers was used for the delivery of anesthesia during transversus abdominis plane block. Lastly, the superficial fascial system (SFS) was subjectively evaluated in all preoperative patients. RESULTS: For flap reconstruction, 11 patients were preoperatively examined with CDUS in order to locate the largest perforators prior to perforator flap reconstruction. Flaps studied included the deep inferior epigastric perforator, anterolateral thigh, tensor fascia lata, thoracodorsal artery perforator, superior gluteal artery perforator, and the gracilis musculocutaneous. Color Doppler ultrasound findings were confirmed intraoperatively for all cases (100%). In 2 (18.2%) of 11 cases, CDUS identified perforators not detected by computed tomography angiography. Twenty-five patients undergoing either abdominoplasty or deep inferior epigastric perforator flap reconstruction had successful intraoperative visualization of the abdominal wall muscular layers, thus allowing administration of transversus abdominis plane blocks by the operating surgeon. Twenty patients undergoing body contouring surgery had preoperative visualization of the SFS. The SFS was found to be varied not only among different patients but also within individual patients. CONCLUSIONS: The newest, miniaturized CDUS technology has a variety of applications that may improve patient outcomes and experience in plastic surgery. Our observations require further investigation to quantify the perceived benefits of this new technology.
引用
- Miller JP, Carney MJ, Lim S, et al. Ultrasound and Plastic Surgery: Clinical Applications of the Newest Technology. Ann Plast Surg. 2018. PMID: 29668508. doi:10.1097/SAP.0000000000001422
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。