文献速递乳房整形与再造美容整形

蒙特利尔隆乳手术(MAMO)模拟器:乳房增大手术培训与能力评估的替代方法

The Montreal Augmentation Mammaplasty Operation (MAMO) Simulator: An Alternative Method to Train and Assess Competence in Breast Augmentation Procedures.
PubMed 文献 · Aesthet Surg J · 2018-01-01

本研究对MAMO模拟器进行面效度、内容效度和结构效度验证,并评估评估量表的信度。14名整形外科住院医师和7名专家整形外科医生在模拟器上完成胸肌下乳房增大手术,视频盲法评估。专家在GRS、MOAT和Checklist评分上均显著高于住院医师,量表信度良好。

要点

  • 专家GRS评分36.9(3.1)显著高于住院医师23.4(2.5),P<0.0001。
  • 专家MOAT评分40(3.2)显著高于住院医师30.4(2.2),P<0.0001。
  • GRS和MOAT的Cronbach's α分别为0.96和0.83,评分者间信度ICC分别为0.93、0.92和0.89。

核心结论

  • 本研究证明该模拟器具有结构效度,评估量表具有信度。

研究设计与样本

  • 招募整形外科住院医师和专家整形外科医生在MAMO模拟器上完成胸肌下乳房增大手术,对操作视频进行盲法评估。
  • 共纳入14名整形外科住院医师和7名专家整形外科医生。

主要发现

  • GRS评分住院医师23.4(2.5)vs 专家36.9(3.1),P<0.0001。
  • MOAT评分住院医师30.4(2.2)vs 专家40(3.2),P<0.0001。
  • Checklist评分住院医师9.7(1.5)vs 专家12(1),P<0.001。
  • 面效度和内容效度各评估参数总体平均分为4.8(0.3)(满分5分)。
  • GRS和MOAT的Cronbach's α分别为0.96和0.83;GRS、MOAT和Checklist的评分者间信度ICC分别为0.93、0.92和0.89。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Surgical residents' exposure to aesthetic procedures remains limited in residency training. The development of the Montreal augmentation mammaplasty operation (MAMO) simulator aims to provide an adjunctive training method and assessment tool to complement the evolving competency-based surgical curriculum. OBJECTIVES: To perform face, content, and construct validations of the MAMO simulator for subpectoral breast augmentation procedures and assess the reliability of the assessment scales used. METHODS: Plastic surgery staff and residents were recruited to perform a subpectoral breast augmentation on the simulator. Video recordings of their performance were blindly evaluated using the objective structured assessment of technical skills (OSATS) system consisting of the global rating scale (GRS), mammaplasty objective assessment tool (MOAT), and a surgery-specific Checklist score. RESULTS: Fourteen plastic surgery residents and seven expert plastic surgeons were enrolled. Experts' performance was significantly higher than residents' according to each of GRS, MOAT, and Checklist scores. Mean values of residents and experts were 23.4 (2.5) vs 36.9 (3.1) (P < 0.0001) for GRS score, 30.4 (2.2) vs 40 (3.2) (P < 0.0001) for MOAT scores, and 9.7 (1.5) vs 12 (1) (P < 0.001) for Checklist scores, respectively. Face and content validations showed excellent results among parameters evaluated, with an overall mean score of 4.8 (0.3) on 5. Cronbach's alpha was 0.96 and 0.83 for GRS and MOAT scores, respectively. Intraclass correlation coefficients for interrater reliability were excellent at 0.93, 0.92, and 0.89 for the GRS, MOAT, and Checklist scores, respectively. CONCLUSIONS: This study proves the construct simulator to be valid and the assessment scales to be reliable.

来源:Aesthet Surg J,查看原文。版权归原作者所有。

引用

  1. Kazan R, Viezel-Mathieu A, Cyr S, et al. The Montreal Augmentation Mammaplasty Operation (MAMO) Simulator: An Alternative Method to Train and Assess Competence in Breast Augmentation Procedures. Aesthet Surg J. 2018. PMID: 29506205. doi:10.1093/asj/sjx267

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。