文献速递显微修复重建创面修复

彩色多普勒超声评估股前外侧皮瓣穿支的可靠性:30条穿支的前瞻性研究

Reliability of Color Doppler Ultrasound Imaging for the Assessment of Anterolateral Thigh Flap Perforators: A Prospective Study of 30 Perforators.
PubMed 文献 · Plast Reconstr Surg · 2018-01-01

本研究为前瞻性队列研究,纳入计划行薄型股前外侧皮瓣头颈重建的患者,术前在手术室由术者行彩色多普勒超声探查穿支。2016年1月至2017年1月成功切取22块皮瓣、定位并使用30条穿支,术前规划与穿支最终位置中位距离5 mm(p=0.002,小于10 mm阈值),超声有效预测穿支性质的比例为90%,定位中位时间3分钟(p=0.0001,短于10分钟)。作者认为术前彩色多普勒超声似乎可靠、准确,适合作为薄型股前外侧皮瓣抬取前患者摆位期间的快速常规评估。

要点

  • 术前规划与穿支最终位置中位距离5 mm,小于10 mm阈值(p=0.002)。
  • 彩色多普勒超声有效预测穿支性质的比例为90%。
  • 穿支定位中位时间3分钟,短于10分钟(p=0.0001)。

核心结论

  • 作者认为术前彩色多普勒超声似乎可靠、准确,适合作为薄型股前外侧皮瓣抬取前患者摆位期间的快速常规评估。

研究设计与样本

  • 前瞻性队列研究,纳入计划以薄型股前外侧穿支皮瓣行头颈重建的患者。
  • 每例患者在手术室、手术即将开始前由作为皮瓣抬取者的术者行大腿彩色多普勒超声探查。
  • 按手术需求寻找穿支,所有病例遵循相同定位方案,采用正交坐标系报告穿支穿过股外侧肌腱膜的位置。
  • 2016年1月至2017年1月成功切取22块薄型股前外侧穿支皮瓣,定位并使用30条穿支。

主要发现

  • 术前彩色多普勒超声规划与穿支最终位置的中位距离为5 mm,统计学上小于10 mm阈值(p=0.002)。
  • 彩色多普勒超声在90%的病例中有效预测了穿支的性质。
  • 穿支彩色多普勒超声定位的中位时间为3分钟,统计学上短于10分钟(p=0.0001)。

关键数值与推荐

  • 术前规划与穿支最终位置的中位距离5 mm,小于10 mm阈值(p=0.002)。
  • 彩色多普勒超声有效预测穿支性质的比例为90%。
  • 穿支定位中位时间3分钟,短于10分钟(p=0.0001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

UNLABELLED: Despite numerous advantages, the anterolateral thigh perforator flap suffers from the variable position and nature of its perforators. The aim of the authors' study was to assess the reliability of preoperative color Doppler ultrasound imaging for the exploration of perforator location and course of anterolateral thigh perforator flaps. A prospective cohort study involving patients for whom head and neck reconstruction was planned with thin anterolateral thigh perforator flaps was conducted. Each patient underwent a color Doppler ultrasound exploration of the thighs, in the operating room, immediately before surgery. The sonographer was the surgeon who raised the flaps. Perforators were sought according to surgical needs, and the same location protocol was followed for all of the cases, using an orthonormal coordinate system to report the passages of the perforators through the vastus lateralis aponeurosis. Between January of 2016 and January of 2017, 22 thin anterolateral thigh perforator flaps were successfully harvested. Thirty perforators were located and used. The median distance between the preoperative color Doppler ultrasound planning and the final location of the perforators was 5 mm, statistically smaller than a 10-mm threshold (p = 0.002). Color Doppler ultrasound effectively predicted the nature of the perforators in 90 percent of the cases. The median duration for perforator color Doppler ultrasound location was 3 minutes, statistically shorter than 10 minutes (p = 0.0001). Preoperative color Doppler ultrasound seems to be reliable, accurate, and compatible with a quick routine assessment during patient setup for the elevation of thin anterolateral thigh perforator flaps. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, II.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Debelmas A, Camuzard O, Aguilar P, et al. Reliability of Color Doppler Ultrasound Imaging for the Assessment of Anterolateral Thigh Flap Perforators: A Prospective Study of 30 Perforators. Plast Reconstr Surg. 2018. PMID: 29481406. doi:10.1097/PRS.0000000000004117

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。